Retrieval of large Occlutech Figula Flex septal defect occluders using a commercially available bioptome: proof of concept. (21st May 2018)
- Record Type:
- Journal Article
- Title:
- Retrieval of large Occlutech Figula Flex septal defect occluders using a commercially available bioptome: proof of concept. (21st May 2018)
- Main Title:
- Retrieval of large Occlutech Figula Flex septal defect occluders using a commercially available bioptome: proof of concept
- Authors:
- Georgiev, Stanimir
Tanase, Daniel
Genz, Thomas
Ewert, Peter
Naumann, Susanne
Pozza, Robert Dalla
Eicken, Andreas - Abstract:
- Abstract: Objectives: This study aimed to develop a method for retrieval of the new meshed nitinol atrial septal defect occluders – Ceraflex and Occlutech. Background: The newly developed atrial septal defect occluders have potential benefits considering implantation, but concerns regarding their removal in case of embolisation have been raised. Methods: Over 21 years, 1449 patients underwent interventional atrial septal defect occlusion in our institution. We reviewed the cases of embolisation of the device, developed a strategy for device removal, and tested it on the benchside and in animal tests. Results: In 11 patients (0.8%), the intended atrial septal defect occlusion was complicated by an embolisation of the device. In contrast to the Amplatzer septal occluders, retrieval of Occlutech devices larger than 16 mm with snare techniques was impossible. In benchside tests, this was confirmed and a new method for removal of large meshed devices was developed. This involved the commercially available Maslanka® biopsy forceps. The feasibility of this technique in vivo was tested in a pig model. During animal tests, using the Maslanka biopsy forceps it was possible to interventionally retrieve embolised Ceraflex and Occlutech devices of different sizes – 10, 16, 30, and 40 mm – into a 12-F sheath. Conclusion: It was impossible to retrieve Occlutech and Ceraflex devices larger than 16 mm into a large sheath in vivo and during benchside tests. However, this was feasible on theAbstract: Objectives: This study aimed to develop a method for retrieval of the new meshed nitinol atrial septal defect occluders – Ceraflex and Occlutech. Background: The newly developed atrial septal defect occluders have potential benefits considering implantation, but concerns regarding their removal in case of embolisation have been raised. Methods: Over 21 years, 1449 patients underwent interventional atrial septal defect occlusion in our institution. We reviewed the cases of embolisation of the device, developed a strategy for device removal, and tested it on the benchside and in animal tests. Results: In 11 patients (0.8%), the intended atrial septal defect occlusion was complicated by an embolisation of the device. In contrast to the Amplatzer septal occluders, retrieval of Occlutech devices larger than 16 mm with snare techniques was impossible. In benchside tests, this was confirmed and a new method for removal of large meshed devices was developed. This involved the commercially available Maslanka® biopsy forceps. The feasibility of this technique in vivo was tested in a pig model. During animal tests, using the Maslanka biopsy forceps it was possible to interventionally retrieve embolised Ceraflex and Occlutech devices of different sizes – 10, 16, 30, and 40 mm – into a 12-F sheath. Conclusion: It was impossible to retrieve Occlutech and Ceraflex devices larger than 16 mm into a large sheath in vivo and during benchside tests. However, this was feasible on the bench and in vivo using the Maslanka biopsy forceps even with the largest available devices. … (more)
- Is Part Of:
- Cardiology in the young. Volume 28:Number 7(2018)
- Journal:
- Cardiology in the young
- Issue:
- Volume 28:Number 7(2018)
- Issue Display:
- Volume 28, Issue 7 (2018)
- Year:
- 2018
- Volume:
- 28
- Issue:
- 7
- Issue Sort Value:
- 2018-0028-0007-0000
- Page Start:
- 955
- Page End:
- 960
- Publication Date:
- 2018-05-21
- Subjects:
- ASD closure, -- device embolisation, -- device retrieval, -- interventional (stents, etc.)
Pediatric cardiology -- Periodicals
618.9212 - Journal URLs:
- http://journals.cambridge.org/action/displayJournal?jid=CTY ↗
- DOI:
- 10.1017/S1047951118000586 ↗
- Languages:
- English
- ISSNs:
- 1047-9511
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library STI - ELD Digital Store
- Ingest File:
- 6747.xml