Monte Carlo simulation of a prototypical patient dosimetry system for fluoroscopic procedures. (17th July 2015)
- Record Type:
- Journal Article
- Title:
- Monte Carlo simulation of a prototypical patient dosimetry system for fluoroscopic procedures. (17th July 2015)
- Main Title:
- Monte Carlo simulation of a prototypical patient dosimetry system for fluoroscopic procedures
- Authors:
- Goertz, Lukas
Tsiamas, Panagiotis
Karellas, Andrew
Sajo, Erno
Zygmanski, Piotr - Abstract:
- Abstract: The purpose of this study is to investigate feasibility of a novel real-time dosimetry method for fluoroscopically guided interventions utilizing thin-film detector arrays in several potential locations with respect to the patient and x-ray equipment. We employed Monte Carlo (MC) simulation to establish the fluoroscopic beam model to determine dosimetric quantities directly from measured doses in thin-film detector arrays at three positions: A—attached to the x-ray source, B—on the couch under the patient and C—attached to the fluoroscopic imager. Next, we developed a calibration method to determine skin dose at the entry of the beam ( ) as well as the dose distribution along each ray of the beam in a water-equivalent patient model. We utilized the concept of water-equivalent thickness to determine the dose inside the patient based on doses measured outside of the patient by the thin-film detector array layers: (a) A, (b) B, or (c) B and C. In the process of calibration we determined a correction factor that characterizes the material-specific response of the detector, backscatter factor and attenuation factor for slab water phantoms of various thicknesses. Application of this method to an anthropomorphic phantom showed accuracy of about 1% for and up to about 10% for integral dose along the beam path when compared to a direct simulation of dose by MC.
- Is Part Of:
- Physics in medicine & biology. Volume 60:Number 15(2015:Aug.)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 60:Number 15(2015:Aug.)
- Issue Display:
- Volume 60, Issue 15 (2015)
- Year:
- 2015
- Volume:
- 60
- Issue:
- 15
- Issue Sort Value:
- 2015-0060-0015-0000
- Page Start:
- 5891
- Page End:
- 5909
- Publication Date:
- 2015-07-17
- Subjects:
- real-time dosimetry -- fluoroscopy -- thin-film detector arrays -- Monte Carlo -- peak skin dose -- entrance dose -- integral dose
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/0031-9155/60/15/5891 ↗