Isotopic effects in the neon fixed point: uncertainty of the calibration data correction. (9th January 2015)
- Record Type:
- Journal Article
- Title:
- Isotopic effects in the neon fixed point: uncertainty of the calibration data correction. (9th January 2015)
- Main Title:
- Isotopic effects in the neon fixed point: uncertainty of the calibration data correction
- Authors:
- Steur, Peter P M
Pavese, Franco
Fellmuth, Bernd
Hermier, Yves
Hill, Kenneth D
Kim, Jin Seog
Lipinski, Leszek
Nagao, Keisuke
Nakano, Tohru
Peruzzi, Andrea
Sparasci, Fernando
Szmyrka-Grzebyk, Anna
Tamura, Osamu
Tew, Weston L
Valkiers, Staf
van Geel, Jan - Abstract:
- Abstract: The neon triple point is one of the defining fixed points of the International Temperature Scale of 1990 (ITS-90). Although recognizing that natural neon is a mixture of isotopes, the ITS-90 definition only states that the neon should be of 'natural isotopic composition', without any further requirements. A preliminary study in 2005 indicated that most of the observed variability in the realized neon triple point temperatures within a range of about 0.5 mK can be attributed to the variability in isotopic composition among different samples of 'natural' neon. Based on the results of an International Project (EUROMET Project No. 770), the Consultative Committee for Thermometry decided to improve the realization of the neon fixed point by assigning the ITS-90 temperature value 24.5561 K to neon with the isotopic composition recommended by IUPAC, accompanied by a quadratic equation to take the deviations from the reference composition into account. In this paper, the uncertainties of the equation are discussed and an uncertainty budget is presented. The resulting standard uncertainty due to the isotopic effect ( k = 1) after correction of the calibration data is reduced to (4 to 40) μK when using neon of 'natural' isotopic composition or to 30 μK when using 20 Ne. For comparison, an uncertainty component of 0.15 mK should be included in the uncertainty budget for the neon triple point if the isotopic composition is unknown, i.e. whenever the correction cannot beAbstract: The neon triple point is one of the defining fixed points of the International Temperature Scale of 1990 (ITS-90). Although recognizing that natural neon is a mixture of isotopes, the ITS-90 definition only states that the neon should be of 'natural isotopic composition', without any further requirements. A preliminary study in 2005 indicated that most of the observed variability in the realized neon triple point temperatures within a range of about 0.5 mK can be attributed to the variability in isotopic composition among different samples of 'natural' neon. Based on the results of an International Project (EUROMET Project No. 770), the Consultative Committee for Thermometry decided to improve the realization of the neon fixed point by assigning the ITS-90 temperature value 24.5561 K to neon with the isotopic composition recommended by IUPAC, accompanied by a quadratic equation to take the deviations from the reference composition into account. In this paper, the uncertainties of the equation are discussed and an uncertainty budget is presented. The resulting standard uncertainty due to the isotopic effect ( k = 1) after correction of the calibration data is reduced to (4 to 40) μK when using neon of 'natural' isotopic composition or to 30 μK when using 20 Ne. For comparison, an uncertainty component of 0.15 mK should be included in the uncertainty budget for the neon triple point if the isotopic composition is unknown, i.e. whenever the correction cannot be applied. … (more)
- Is Part Of:
- Metrologia. Volume 52:Number 1(2015:Feb.)
- Journal:
- Metrologia
- Issue:
- Volume 52:Number 1(2015:Feb.)
- Issue Display:
- Volume 52, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 52
- Issue:
- 1
- Issue Sort Value:
- 2015-0052-0001-0000
- Page Start:
- 104
- Page End:
- 110
- Publication Date:
- 2015-01-09
- Subjects:
- neon -- triple point -- isotopic composition -- uncertainty
Weights and measures -- Periodicals
Weights and Measures -- Periodicals
530.805 - Journal URLs:
- http://iopscience.iop.org/0026-1394/ ↗
http://www.iop.org/ej/journal/0026-1394 ↗
http://www.iop.org/ ↗
http://www.ingentaconnect.com/content/bipm/met ↗ - DOI:
- 10.1088/0026-1394/52/1/104 ↗
- Languages:
- English
- ISSNs:
- 0026-1394
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 6731.xml