Optimization of Compound Plate Preparation to Address Precipitation Issue in Mammalian A549 Cytotoxicity Assay. (June 2016)
- Record Type:
- Journal Article
- Title:
- Optimization of Compound Plate Preparation to Address Precipitation Issue in Mammalian A549 Cytotoxicity Assay. (June 2016)
- Main Title:
- Optimization of Compound Plate Preparation to Address Precipitation Issue in Mammalian A549 Cytotoxicity Assay
- Authors:
- Raghavendra Achar, Vijayashree Gauribidanur
Barde, Shubhada Pramod
Mallya, Meenakshy Venkatesh
Awasthy, Disha
Narayan, Chandan - Abstract:
- This study illustrates the optimization of low-volume dispensing on a liquid handling system (LHS) to overcome the precipitation of compounds in the mammalian cytotoxicity assay with low dimethyl sulfoxide (DMSO) tolerance. All compounds at AstraZeneca Bangalore are tested in the mammalian cytotoxicity assay. In order to maintain the DMSO levels, serially diluted plates were prepared in DMSO/water. It was observed that some of the compounds precipitated. The IC50 data for such compounds were therefore erratic. To circumvent the problem of compound precipitation, the LHS was optimized to dispense low volumes (<1 µL). The plates were serially diluted using neat DMSO. Since the dilution was done using neat DMSO, there were no issues with precipitation. The serially diluted sample (0.5 µL) from the plate was stamped onto the assay plate to give the desired DMSO concentration. No significant differences in IC50 data were observed for 1 µL dispenses made from DMSO/water and 0.5 µL dispenses from neat DMSO for the samples with no precipitation issues. These data therefore gave us the confidence to switch over to 0.5 µL dispenses for the cytotoxicity assay to address the precipitation issue. However, precipitation of samples in the assay buffer is beyond the scope of this discussion.
- Is Part Of:
- Journal of laboratory automation. Volume 21:Number 3(2016:Jun.)
- Journal:
- Journal of laboratory automation
- Issue:
- Volume 21:Number 3(2016:Jun.)
- Issue Display:
- Volume 21, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 21
- Issue:
- 3
- Issue Sort Value:
- 2016-0021-0003-0000
- Page Start:
- 423
- Page End:
- 431
- Publication Date:
- 2016-06
- Subjects:
- Biomek FX liquid handler -- low-volume dispense -- mammalian A549 cytotoxicity assay -- compound management
Medical laboratory technology -- Periodicals
Laboratories -- Equipment and supplies -- Periodicals
Diagnosis, Laboratory -- Periodicals
616.075 - Journal URLs:
- http://journals.sagepub.com/home/jla ↗
http://online.sagepub.com/ ↗ - DOI:
- 10.1177/2211068215594768 ↗
- Languages:
- English
- ISSNs:
- 2211-0682
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.001000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: