Reliability of pulse waveform separation analysis: effects of posture and fasting. Issue 3 (March 2017)
- Record Type:
- Journal Article
- Title:
- Reliability of pulse waveform separation analysis: effects of posture and fasting. Issue 3 (March 2017)
- Main Title:
- Reliability of pulse waveform separation analysis
- Authors:
- Stoner, Lee
Credeur, Daniel
Fryer, Simon
Faulkner, James
Lambrick, Danielle
Gibbs, Bethany Barone - Abstract:
- Abstract : Objective: Oscillometric pulse wave analysis devices enable, with relative simplicity and objectivity, the measurement of central hemodynamic parameters. The important parameters are central blood pressures and indices of arterial wave reflection, including wave separation analysis (backward pressure component P b and reflection magnitude). This study sought to determine whether the measurement precision (between-day reliability) of P b and reflection magnitude: exceeds the criterion for acceptable reliability; and is affected by posture (supine, seated) and fasting state. Methods: Twenty healthy adults (50% female, 27.9 years, 24.2 kg/m 2 ) were tested on six different mornings: 3 days fasted, 3 days nonfasted condition. On each occasion, participants were tested in supine and seated postures. Oscillometric pressure waveforms were recorded on the left upper arm. Results: The criterion intra-class correlation coefficient value of 0.75 was exceeded for P b (0.76) and reflection magnitude (0.77) when participants were assessed under the combined supine-fasted condition. The intra-class correlation coefficient was lowest for P b in seated-nonfasted condition (0.57), and lowest for reflection magnitude in the seated-fasted condition (0.56). For P b, the smallest detectible change that must be exceeded in order for a significant change to occur in an individual was 2.5 mmHg, and for reflection magnitude, the smallest detectable change was 8.5%. Conclusion: AssessmentsAbstract : Objective: Oscillometric pulse wave analysis devices enable, with relative simplicity and objectivity, the measurement of central hemodynamic parameters. The important parameters are central blood pressures and indices of arterial wave reflection, including wave separation analysis (backward pressure component P b and reflection magnitude). This study sought to determine whether the measurement precision (between-day reliability) of P b and reflection magnitude: exceeds the criterion for acceptable reliability; and is affected by posture (supine, seated) and fasting state. Methods: Twenty healthy adults (50% female, 27.9 years, 24.2 kg/m 2 ) were tested on six different mornings: 3 days fasted, 3 days nonfasted condition. On each occasion, participants were tested in supine and seated postures. Oscillometric pressure waveforms were recorded on the left upper arm. Results: The criterion intra-class correlation coefficient value of 0.75 was exceeded for P b (0.76) and reflection magnitude (0.77) when participants were assessed under the combined supine-fasted condition. The intra-class correlation coefficient was lowest for P b in seated-nonfasted condition (0.57), and lowest for reflection magnitude in the seated-fasted condition (0.56). For P b, the smallest detectible change that must be exceeded in order for a significant change to occur in an individual was 2.5 mmHg, and for reflection magnitude, the smallest detectable change was 8.5%. Conclusion: Assessments of P b and reflection magnitude are as follows: exceed the criterion for acceptable reliability; and are most reliable when participants are fasted in a supine position. The demonstrated reliability suggests sufficient precision to detect clinically meaningful changes in reflection magnitude and P b . … (more)
- Is Part Of:
- Journal of hypertension. Volume 35:Issue 3(2017:Mar.)
- Journal:
- Journal of hypertension
- Issue:
- Volume 35:Issue 3(2017:Mar.)
- Issue Display:
- Volume 35, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 35
- Issue:
- 3
- Issue Sort Value:
- 2017-0035-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-03
- Subjects:
- arterial wave reflection -- augmentation index -- central blood pressure -- fasting -- oscillometry -- postprandial -- posture -- pulse wave analysis -- reproducibility
Hypertension -- Periodicals
Hypertension -- Periodicals
616.132005 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://journals.lww.com/jhypertension/pages/default.aspx ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00004872-000000000-00000 ↗
http://www.jhypertension.com/ ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/HJH.0000000000001182 ↗
- Languages:
- English
- ISSNs:
- 1473-5598
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5004.510000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 6724.xml