Exploiting Kalman Filtering Non-linear Exponential Fitting to Promote the Energy Resolution of 137Cs and 60Co Gamma Ray Spectra. Issue 3 (March 2017)
- Record Type:
- Journal Article
- Title:
- Exploiting Kalman Filtering Non-linear Exponential Fitting to Promote the Energy Resolution of 137Cs and 60Co Gamma Ray Spectra. Issue 3 (March 2017)
- Main Title:
- Exploiting Kalman Filtering Non-linear Exponential Fitting to Promote the Energy Resolution of 137Cs and 60Co Gamma Ray Spectra
- Authors:
- Guo, Huiping
Tian, Chenyang
Xue, Hongbin
Lv, Ning
Wei, Yingguang
Fu, Guangzhi
Lv, Wenhui
Zhao, Kuo
Hou, Yijie - Abstract:
- Abstract : Abstract: For 137 Cs and 60 Co gamma ray spectra, gamma ray energy is proportional to the amplitude of the pulse signal, and energy resolution can be improved by pulse signal processing with mathematical algorithms. Influenced by system measurement noise and baseline fluctuation, the pulse amplitude is difficult to calculate accurately. A method that combines the Kalman filter baseline estimation with the non-linear exponential fitting has been used. By this method, the pulse signal is divided into two parts: one is the raising edge before the pulse peak, and another is after the pulse peak. The pulse amplitude equals the difference between the pulse starting height and the pulse peak height. The pulse starting height is obtained by Kalman filter baseline estimation on the rising edge of the pulse starting point. The pulse peak height is calculated by nonlinear exponential fitting on the falling edge of the pulse highest point. When the sampling rate is 100 MHz, the pulse signals obtained from a Cd(Zn)Te detector are analyzed by this method. Results have shown that the processed pulses have a more distinguishable amplitude distribution; energy resolution for the 137 Cs spectrum is approximately 2.97% at 662 keV (~19.66 keV FWHM), and for the 60 Co spectrum it is 2.61% at 1, 332 keV (~34.76 keV FWHM).
- Is Part Of:
- Health physics. Volume 112:Issue 3(2017:Mar.)
- Journal:
- Health physics
- Issue:
- Volume 112:Issue 3(2017:Mar.)
- Issue Display:
- Volume 112, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 112
- Issue:
- 3
- Issue Sort Value:
- 2017-0112-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-03
- Subjects:
- 137Cs -- 60Co -- algorithm -- gamma radiation
Biophysics -- Periodicals
Health Physics -- periodicals
Radiation Protection -- periodicals
Radiotherapy -- periodicals
Medische fysica
Electronic journals
612.01448 - Journal URLs:
- http://journals.lww.com/health-physics/pages/default.aspx ↗
http://www.health-physics.com ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/HP.0000000000000606 ↗
- Languages:
- English
- ISSNs:
- 0017-9078
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4275.100000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6723.xml