Differences in Use of Glucose Rate of Change (ROC) Arrows to Adjust Insulin Therapy Among Individuals With Type 1 and Type 2 Diabetes Who Use Continuous Glucose Monitoring (CGM). (September 2016)
- Record Type:
- Journal Article
- Title:
- Differences in Use of Glucose Rate of Change (ROC) Arrows to Adjust Insulin Therapy Among Individuals With Type 1 and Type 2 Diabetes Who Use Continuous Glucose Monitoring (CGM). (September 2016)
- Main Title:
- Differences in Use of Glucose Rate of Change (ROC) Arrows to Adjust Insulin Therapy Among Individuals With Type 1 and Type 2 Diabetes Who Use Continuous Glucose Monitoring (CGM)
- Authors:
- Pettus, Jeremy
Edelman, Steven V. - Abstract:
- Objective: To understand differences between individuals with type 1 diabetes (T1D) and type 2 diabetes (T2D) in utilization of continuous glucose monitoring (CGM) data to adjust insulin therapy, either continuous subcutaneous insulin infusion (CSII) or multiple daily insulin injections (MDI). Methods: We surveyed 300 individuals who regularly used real-time CGM, using 70 questions to obtain information about general CGM use and response to glucose rate of change (ROC) arrows. Results: The survey was completed by 222 T1D and 78 T2D respondents treated with intensive insulin therapy. T1D respondents included CSII (n = 166) and MDI (n = 56) users. T2D respondents were more balanced: 34 (44%) versus 44 (56%), respectively. A larger percentage of T1D then T2D respondents reported a constant use of CGM (85% vs 61%, P < .001). T1D and T2D respondents reported similar substantial increases in correction dosages in response to rapidly increasing glucose (>3 mg/dL/min; 2 arrows up): +140% versus +136%, P = .4534. However, T1D respondents reported making smaller correction dosage reductions than T2D respondents in response to rapidly decreasing glucose (−42% vs −80%, P < .001). Differences between T1D and T2D respondents were also observed in mealtime dosage adjustments in response to rapidly increasing glucose compared to when glucose is stable (flat arrow) at 110 mg/dl: +81% versus +108%, respectively ( P = .003). Although these adjustments are statistically different, both areObjective: To understand differences between individuals with type 1 diabetes (T1D) and type 2 diabetes (T2D) in utilization of continuous glucose monitoring (CGM) data to adjust insulin therapy, either continuous subcutaneous insulin infusion (CSII) or multiple daily insulin injections (MDI). Methods: We surveyed 300 individuals who regularly used real-time CGM, using 70 questions to obtain information about general CGM use and response to glucose rate of change (ROC) arrows. Results: The survey was completed by 222 T1D and 78 T2D respondents treated with intensive insulin therapy. T1D respondents included CSII (n = 166) and MDI (n = 56) users. T2D respondents were more balanced: 34 (44%) versus 44 (56%), respectively. A larger percentage of T1D then T2D respondents reported a constant use of CGM (85% vs 61%, P < .001). T1D and T2D respondents reported similar substantial increases in correction dosages in response to rapidly increasing glucose (>3 mg/dL/min; 2 arrows up): +140% versus +136%, P = .4534. However, T1D respondents reported making smaller correction dosage reductions than T2D respondents in response to rapidly decreasing glucose (−42% vs −80%, P < .001). Differences between T1D and T2D respondents were also observed in mealtime dosage adjustments in response to rapidly increasing glucose compared to when glucose is stable (flat arrow) at 110 mg/dl: +81% versus +108%, respectively ( P = .003). Although these adjustments are statistically different, both are large. Conclusions: CGM users often rely on ROC information when determining insulin doses and tend to be more aggressive in their insulin adjustments despite differences in type of diabetes. … (more)
- Is Part Of:
- Journal of diabetes science and technology. Volume 10:Number 5(2016:Sep.)
- Journal:
- Journal of diabetes science and technology
- Issue:
- Volume 10:Number 5(2016:Sep.)
- Issue Display:
- Volume 10, Issue 5 (2016)
- Year:
- 2016
- Volume:
- 10
- Issue:
- 5
- Issue Sort Value:
- 2016-0010-0005-0000
- Page Start:
- 1087
- Page End:
- 1093
- Publication Date:
- 2016-09
- Subjects:
- continuous glucose monitoring -- rate of change -- type 1 diabetes -- type 2 diabetes -- insulin pump -- multiple daily insulin injections
Diabetes -- Periodicals
Medical technology -- Periodicals
Diabetes Mellitus -- Periodicals
616.462005 - Journal URLs:
- http://ejournals.ebsco.com/direct.asp?JournalID=712321 ↗
http://www.jodsat.org/about.html ↗
http://online.sagepub.com/ ↗ - DOI:
- 10.1177/1932296816639069 ↗
- Languages:
- English
- ISSNs:
- 1932-2968
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6715.xml