Laboratory evaluation of a low-cost, real-time, aerosol multi-sensor. Issue 7 (3rd July 2018)
- Record Type:
- Journal Article
- Title:
- Laboratory evaluation of a low-cost, real-time, aerosol multi-sensor. Issue 7 (3rd July 2018)
- Main Title:
- Laboratory evaluation of a low-cost, real-time, aerosol multi-sensor
- Authors:
- Vercellino, Robert J.
Sleeth, Darrah K.
Handy, Rodney G.
Min, Kyeong T.
Collingwood, Scott C. - Abstract:
- ABSTRACT: Exposure to occupational aerosols are a known hazard in many industry sectors and can be a risk factor for several respiratory diseases. In this study, a laboratory evaluation of low-cost aerosol sensors, the Dylos DC1700 and a modified Dylos known as the Utah Modified Dylos Sensor (UMDS), was performed to assess the sensors' efficiency in sampling respirable and inhalable dust at high concentrations, which are most common in occupational settings. Dust concentrations were measured in a low-speed wind tunnel with 3 UMDSs, collocated with an aerosol spectrometer (Grimm 1.109) and gravimetric respirable and inhalable samplers. A total of 10 tests consisting of 5 different concentrations and 2 test aerosols, Arizona road dust and aluminum oxide, were conducted. For the Arizona road dust, total particle count was strongly related between the spectrometer and the UMDS with a coefficient of determination (R 2 ) between 0.86–0.92. Particle count concentrations measured with the UMDS were converted to mass and also were related with gravimetrically collected inhalable and respirable dust. The UMDS small bin (i.e., all particles) compared to the inhalable sampler yielded an R 2 of 0.86–0.92, and the large bin subtracted from the small bin (i.e., only the smallest particles) compared to the respirable sampler yielded an R 2 of 0.93–0.997. Tests with the aluminum oxide demonstrated a substantially lower relationship across all comparisons. Furthermore, assessment ofABSTRACT: Exposure to occupational aerosols are a known hazard in many industry sectors and can be a risk factor for several respiratory diseases. In this study, a laboratory evaluation of low-cost aerosol sensors, the Dylos DC1700 and a modified Dylos known as the Utah Modified Dylos Sensor (UMDS), was performed to assess the sensors' efficiency in sampling respirable and inhalable dust at high concentrations, which are most common in occupational settings. Dust concentrations were measured in a low-speed wind tunnel with 3 UMDSs, collocated with an aerosol spectrometer (Grimm 1.109) and gravimetric respirable and inhalable samplers. A total of 10 tests consisting of 5 different concentrations and 2 test aerosols, Arizona road dust and aluminum oxide, were conducted. For the Arizona road dust, total particle count was strongly related between the spectrometer and the UMDS with a coefficient of determination (R 2 ) between 0.86–0.92. Particle count concentrations measured with the UMDS were converted to mass and also were related with gravimetrically collected inhalable and respirable dust. The UMDS small bin (i.e., all particles) compared to the inhalable sampler yielded an R 2 of 0.86–0.92, and the large bin subtracted from the small bin (i.e., only the smallest particles) compared to the respirable sampler yielded an R 2 of 0.93–0.997. Tests with the aluminum oxide demonstrated a substantially lower relationship across all comparisons. Furthermore, assessment of intra-instrument variability was consistent for all instruments, but inter-instrument variability indicated that each instrument requires its own calibration equation to yield accurate exposure estimates. Overall, it appears that the UMDS can be used as a low-cost tool to estimate respirable and inhalable concentrations found in many workplaces. Future studies will focus on deployment of a UMDS network in an occupational setting. … (more)
- Is Part Of:
- Journal of occupational and environmental hygiene. Volume 15:Issue 7(2018)
- Journal:
- Journal of occupational and environmental hygiene
- Issue:
- Volume 15:Issue 7(2018)
- Issue Display:
- Volume 15, Issue 7 (2018)
- Year:
- 2018
- Volume:
- 15
- Issue:
- 7
- Issue Sort Value:
- 2018-0015-0007-0000
- Page Start:
- 559
- Page End:
- 567
- Publication Date:
- 2018-07-03
- Subjects:
- Dust -- real-time detection systems -- sensor technologies
Industrial hygiene -- Periodicals
Environmental health -- Periodicals
Medicine, Industrial -- Periodicals
Occupational Health -- Periodicals
Environmental Exposure -- Periodicals
Environmental Health -- Periodicals
Occupational Exposure -- Periodicals
Hygiène industrielle -- Périodiques
Hygiène du milieu -- Périodiques
Médecine du travail -- Périodiques
613.62 - Journal URLs:
- http://www.tandfonline.com/ ↗
- DOI:
- 10.1080/15459624.2018.1468565 ↗
- Languages:
- English
- ISSNs:
- 1545-9624
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5026.080500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6700.xml