Magnetic resonance elastography (MRE) for measurement of muscle stiffness of the shoulder: feasibility with a 3 T MRI system. (September 2016)
- Record Type:
- Journal Article
- Title:
- Magnetic resonance elastography (MRE) for measurement of muscle stiffness of the shoulder: feasibility with a 3 T MRI system. (September 2016)
- Main Title:
- Magnetic resonance elastography (MRE) for measurement of muscle stiffness of the shoulder: feasibility with a 3 T MRI system
- Authors:
- Hong, Sun Hwa
Hong, Suk-Joo
Yoon, Joon-Shik
Oh, Chang-Hyun
Cha, Jang Gyu
Kim, Hee Kyung
Bolster, Bradley - Abstract:
- Background: Magnetic resonance elastography (MRE) at 3 T MR has the potential to improve the objective detection of skeletal muscle stiffness. Purpose: To determine the feasibility of MRE using 3 T MR for measurement of the stiffness of shoulder muscles in subjects. Material and Methods: This study prospectively evaluated 16 healthy subjects (mean age, 29.8 years; range, 25–51 years). MRE was acquired with 3 T MR through the use of a 2D-gradient-echo-based MRE sequence at two different excitation frequencies (90 and 120 Hz). The mean stiffness values (MSV) of the trapezius and infraspinatus muscles were measured by two radiologists. Differences between the MSV in the x, y, and z motion-sensitization directions were assessed. Inter-observer agreement was also measured. Results: The MSV of the trapezius muscle were 2.72 kPa ± 0.6 (SD) at 90 Hz and 4.66 kPa ± 1.2 at 120 Hz, while the MSV for the infraspinatus muscle were 3.2 kPa ± 0.52 at 90 Hz and 4.38 kPa ± 0.92 at 120 Hz. The MSV for both muscles were significantly higher at 120 Hz than at 90 Hz ( P < 0.05). The MSV in the three different directions were significantly different from each other in the infraspinatus muscle ( P < 0.05). Levels of inter-observer agreement regarding MSV were good to excellent for both the trapezius (intraclass correlation coefficient [ICC] = 0.979–0.996) and infraspinatus muscles (ICC = 0.614–0.943). Conclusion: MRE at 3 T is a feasible technique for the evaluation of shoulder muscle stiffness.Background: Magnetic resonance elastography (MRE) at 3 T MR has the potential to improve the objective detection of skeletal muscle stiffness. Purpose: To determine the feasibility of MRE using 3 T MR for measurement of the stiffness of shoulder muscles in subjects. Material and Methods: This study prospectively evaluated 16 healthy subjects (mean age, 29.8 years; range, 25–51 years). MRE was acquired with 3 T MR through the use of a 2D-gradient-echo-based MRE sequence at two different excitation frequencies (90 and 120 Hz). The mean stiffness values (MSV) of the trapezius and infraspinatus muscles were measured by two radiologists. Differences between the MSV in the x, y, and z motion-sensitization directions were assessed. Inter-observer agreement was also measured. Results: The MSV of the trapezius muscle were 2.72 kPa ± 0.6 (SD) at 90 Hz and 4.66 kPa ± 1.2 at 120 Hz, while the MSV for the infraspinatus muscle were 3.2 kPa ± 0.52 at 90 Hz and 4.38 kPa ± 0.92 at 120 Hz. The MSV for both muscles were significantly higher at 120 Hz than at 90 Hz ( P < 0.05). The MSV in the three different directions were significantly different from each other in the infraspinatus muscle ( P < 0.05). Levels of inter-observer agreement regarding MSV were good to excellent for both the trapezius (intraclass correlation coefficient [ICC] = 0.979–0.996) and infraspinatus muscles (ICC = 0.614–0.943). Conclusion: MRE at 3 T is a feasible technique for the evaluation of shoulder muscle stiffness. Extended application of skeletal muscle MRE at 3 T will contribute to the evaluation and treatment of skeletal muscle disorders. … (more)
- Is Part Of:
- Acta radiologica. Volume 57:Number 9(2016:Sep.)
- Journal:
- Acta radiologica
- Issue:
- Volume 57:Number 9(2016:Sep.)
- Issue Display:
- Volume 57, Issue 9 (2016)
- Year:
- 2016
- Volume:
- 57
- Issue:
- 9
- Issue Sort Value:
- 2016-0057-0009-0000
- Page Start:
- 1099
- Page End:
- 1106
- Publication Date:
- 2016-09
- Subjects:
- Magnetic resonance elastography (MRE) -- skeletal muscle -- shoulder -- 3 Tesla
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1177/0284185115571987 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6668.xml