Feasibility of an Intraluminal Bypass Device in Low Colorectal Anastomosis: Preliminary Results in a Porcine Model. (June 2016)
- Record Type:
- Journal Article
- Title:
- Feasibility of an Intraluminal Bypass Device in Low Colorectal Anastomosis: Preliminary Results in a Porcine Model. (June 2016)
- Main Title:
- Feasibility of an Intraluminal Bypass Device in Low Colorectal Anastomosis
- Authors:
- Willenz, Udi
Wasserberg, Nir
Botero-Anug, Ana Maria
Greenberg, Ron - Abstract:
- Background : The Cologuard CG-100 is a novel intraluminal bypass device designed to reduce the clinical outcomes associated with low colorectal anastomotic leak. The device is inserted transanally, anchored to the colon above the anastomosis, and deployed intraluminally to cover the anastomosis from within. The purpose of this study was to evaluate the safety and performance of the device in a porcine model. Method : Twelve pigs underwent low colorectal anastomosis with insertion of the Cologuard CG-100 device. Contrast material injection, abdominal X-ray, and histologic studies were used to evaluate sealing quality, device positioning, and tissue damage, respectively. The surgeons completed a usability and satisfaction questionnaire after completion of the procedure. Results : Absolute sealing was observed in all 4 animals euthanized immediately after surgery. In the other 8 animals, the device was kept in situ for 10 days and then extracted. X-ray films with injection of contrast material through a designated injection tube before device removal showed that the sheath and ring were correctly placed. No leak was demonstrated. There were no device-related adverse events, and no critical histological abnormalities were noted in the bowel area that was compressed by the device. The device was found to be easy to insert, position, and extract. Conclusion : The Cologuard CG-100 device efficiently reduced contact between fecal content and low colorectal anastomosis in a porcineBackground : The Cologuard CG-100 is a novel intraluminal bypass device designed to reduce the clinical outcomes associated with low colorectal anastomotic leak. The device is inserted transanally, anchored to the colon above the anastomosis, and deployed intraluminally to cover the anastomosis from within. The purpose of this study was to evaluate the safety and performance of the device in a porcine model. Method : Twelve pigs underwent low colorectal anastomosis with insertion of the Cologuard CG-100 device. Contrast material injection, abdominal X-ray, and histologic studies were used to evaluate sealing quality, device positioning, and tissue damage, respectively. The surgeons completed a usability and satisfaction questionnaire after completion of the procedure. Results : Absolute sealing was observed in all 4 animals euthanized immediately after surgery. In the other 8 animals, the device was kept in situ for 10 days and then extracted. X-ray films with injection of contrast material through a designated injection tube before device removal showed that the sheath and ring were correctly placed. No leak was demonstrated. There were no device-related adverse events, and no critical histological abnormalities were noted in the bowel area that was compressed by the device. The device was found to be easy to insert, position, and extract. Conclusion : The Cologuard CG-100 device efficiently reduced contact between fecal content and low colorectal anastomosis in a porcine model and is easily deployed and extracted. It holds promise for possible clinical use pending further studies. … (more)
- Is Part Of:
- Surgical innovation. Volume 23:Number 3(2016:Jun.)
- Journal:
- Surgical innovation
- Issue:
- Volume 23:Number 3(2016:Jun.)
- Issue Display:
- Volume 23, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 23
- Issue:
- 3
- Issue Sort Value:
- 2016-0023-0003-0000
- Page Start:
- 298
- Page End:
- 304
- Publication Date:
- 2016-06
- Subjects:
- colorectal surgery -- anastomotic leak -- intraluminal device
Surgery, Operative -- Periodicals
Endoscopic surgery -- Periodicals
Laparoscopic surgery -- Periodicals
Surgical Procedures, Operative -- Periodicals
Surgical Procedures, Minimally Invasive -- Periodicals
Diffusion of Innovation -- Periodicals
Chirurgie opératoire -- Périodiques
Chirurgie endoscopique -- Périodiques
Chirurgie laparoscopique -- Périodiques
617.91 - Journal URLs:
- http://journals.sagepub.com/home/sri ↗
http://sri.sagepub.com/ ↗
http://www.sagepub.com/journalsProdDesc.nav?prodId=Journal201793 ↗
http://www.sagepublications.com/ ↗ - DOI:
- 10.1177/1553350615617250 ↗
- Languages:
- English
- ISSNs:
- 1553-3506
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6669.xml