Ex vivo simulation of cardiopulmonary bypass with human blood for hemocompatibility testing. (July 2016)
- Record Type:
- Journal Article
- Title:
- Ex vivo simulation of cardiopulmonary bypass with human blood for hemocompatibility testing. (July 2016)
- Main Title:
- Ex vivo simulation of cardiopulmonary bypass with human blood for hemocompatibility testing
- Authors:
- Teligui, Leylah
Dalmayrac, Emilie
Corbeau, Jean-Jacques
Bouquet, Emmanuelle
Godon, Alban
Denommé, Anne-Sophie
Binuani, Partrice
Verron, Laurence
Boer, Christa
Baufreton, Christophe - Abstract:
- Object: Experimental circuits for biomaterial surface testing are frequently limited by the tested blood volume, composition of the circuit, flow conditions and the use of animal blood. This report describes an ex vivo set-up for simulated cardiopulmonary bypass with human blood perfusion. We investigated the clinical generalizability of the observed effects on hematological and metabolic parameters and the hemocompatibility of the system. Methods: The simulated cardiopulmonary bypass circuit consisted of a heparin-coated tubing system connected to an oxygenator and a venous reservoir. Normothermic flow of blood obtained from healthy donors was maintained at 2.4 L/min/m 2 by a roller pump. Heparin was dosed to obtain a target activated clotting time (ACT) ⩾500 s. Blood was drawn at baseline and 0, 10, 60 and 120 minutes following the initiation of blood flow to determine hematological and metabolic parameters and the hemocompatibility of the extracorporeal system. Data were analyzed using repeated measures ANOVA. Results: Two hours of blood perfusion resulted in a small, but clinically unimportant reduction in hematocrit, whereas hemoglobin levels and red blood cell, platelet and leukocyte counts remained stable. There was a significant increase in ACT throughout the experiment. While pO2 levels and the pH remained unaltered during the experiment, pCO2 values decreased from 51 ± 6 mmHg at T0 to 41 ± 3 mmHg at T120 (p<0.001). Simulated cardiopulmonary bypass induced aObject: Experimental circuits for biomaterial surface testing are frequently limited by the tested blood volume, composition of the circuit, flow conditions and the use of animal blood. This report describes an ex vivo set-up for simulated cardiopulmonary bypass with human blood perfusion. We investigated the clinical generalizability of the observed effects on hematological and metabolic parameters and the hemocompatibility of the system. Methods: The simulated cardiopulmonary bypass circuit consisted of a heparin-coated tubing system connected to an oxygenator and a venous reservoir. Normothermic flow of blood obtained from healthy donors was maintained at 2.4 L/min/m 2 by a roller pump. Heparin was dosed to obtain a target activated clotting time (ACT) ⩾500 s. Blood was drawn at baseline and 0, 10, 60 and 120 minutes following the initiation of blood flow to determine hematological and metabolic parameters and the hemocompatibility of the extracorporeal system. Data were analyzed using repeated measures ANOVA. Results: Two hours of blood perfusion resulted in a small, but clinically unimportant reduction in hematocrit, whereas hemoglobin levels and red blood cell, platelet and leukocyte counts remained stable. There was a significant increase in ACT throughout the experiment. While pO2 levels and the pH remained unaltered during the experiment, pCO2 values decreased from 51 ± 6 mmHg at T0 to 41 ± 3 mmHg at T120 (p<0.001). Simulated cardiopulmonary bypass induced a two-fold increase in C3a (p=0.001) while tissue factor was decreased from 44 ± 14 pg/mL at T0 to 38 ± 13 pg/mL at T120 (p=0.009). Levels of CD40L, prothrombin fragment 1+2, β-thromboglobulin and factor VIIa remained stable over time. Conclusion: The ex vivo set-up for simulated cardiopulmonary bypass mimicked the clinical cardiosurgical setting. Exposure of fresh donor blood to the extracorporeal circuit showed a good hemocompatibility, indicated by maintained hematological parameters and a mild immune response. … (more)
- Is Part Of:
- Perfusion. Volume 31:Number 5(2016)
- Journal:
- Perfusion
- Issue:
- Volume 31:Number 5(2016)
- Issue Display:
- Volume 31, Issue 5 (2016)
- Year:
- 2016
- Volume:
- 31
- Issue:
- 5
- Issue Sort Value:
- 2016-0031-0005-0000
- Page Start:
- 376
- Page End:
- 383
- Publication Date:
- 2016-07
- Subjects:
- cardiopulmonary bypass -- hemostasis -- biosurface -- coating -- heparin
Perfusion (Physiology) -- Periodicals
Blood -- Circulation, Artificial -- Periodicals
Heart -- Surgery -- Periodicals
Extracorporeal Circulation -- Periodicals
Perfusion -- Periodicals
Circulation extracorporelle -- Périodiques
Perfusion -- Périodiques
617.41 - Journal URLs:
- http://prf.sagepub.com/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/0267659115599454 ↗
- Languages:
- English
- ISSNs:
- 0267-6591
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6671.xml