Standardized Protocol to Analyze Computed Tomography Imaging of Type B Aortic Dissections. (June 2016)
- Record Type:
- Journal Article
- Title:
- Standardized Protocol to Analyze Computed Tomography Imaging of Type B Aortic Dissections. (June 2016)
- Main Title:
- Standardized Protocol to Analyze Computed Tomography Imaging of Type B Aortic Dissections
- Authors:
- Kamman, Arnoud V.
van Herwaarden, Joost A.
Orrico, Matteo
Nauta, Foeke J. H.
Heijmen, Robin H.
Moll, Frans L.
Trimarchi, Santi - Abstract:
- Purpose: To propose a standard measuring protocol for type B aortic dissections so as to improve comparability between studies reporting aortic dimensions.Methods: Fifteen computed tomography (CT) scans of type B aortic dissections were measured with a standard protocol by 2 independent observers using postprocessing software. The following parameters were assessed: true, false, and total lumen diameter; true and false lumen volume; and entry tear size, location, and number. Diameters were measured in a perpendicular plane at 2, 10, and 20 cm from the left subclavian artery and 5 cm from the most distal renal artery. True lumen volume was assessed from the left subclavian artery to the aortic bifurcation, while the false lumen volume was from the start to end up to the aortic bifurcation. Entry tear location was assessed in relation to the left subclavian artery. Intra- and interobserver repeatability and agreement were evaluated using the Bland-Altman method, an a priori set of acceptable differences, and Lin's concordance correlation coefficient (LCCC).Results: Intra- and interobserver mean differences for aortic diameter and true and false lumen volumes were generally within the limits of agreement and the a priori differences; the LCCC showed excellent agreement. Entry tear location, size, and number were difficult to measure in a repeatable manner, with inconsistent correlation coefficients, especially between the 2 observers.Conclusion: This protocol showed acceptablePurpose: To propose a standard measuring protocol for type B aortic dissections so as to improve comparability between studies reporting aortic dimensions.Methods: Fifteen computed tomography (CT) scans of type B aortic dissections were measured with a standard protocol by 2 independent observers using postprocessing software. The following parameters were assessed: true, false, and total lumen diameter; true and false lumen volume; and entry tear size, location, and number. Diameters were measured in a perpendicular plane at 2, 10, and 20 cm from the left subclavian artery and 5 cm from the most distal renal artery. True lumen volume was assessed from the left subclavian artery to the aortic bifurcation, while the false lumen volume was from the start to end up to the aortic bifurcation. Entry tear location was assessed in relation to the left subclavian artery. Intra- and interobserver repeatability and agreement were evaluated using the Bland-Altman method, an a priori set of acceptable differences, and Lin's concordance correlation coefficient (LCCC).Results: Intra- and interobserver mean differences for aortic diameter and true and false lumen volumes were generally within the limits of agreement and the a priori differences; the LCCC showed excellent agreement. Entry tear location, size, and number were difficult to measure in a repeatable manner, with inconsistent correlation coefficients, especially between the 2 observers.Conclusion: This protocol showed acceptable repeatability for aortic diameter and aortic volume measurements. Assessment of entry tears proved challenging and associated with less favorable results. Additionally, investigators are urged to be more transparent regarding the measurement methodology used in studies describing aortic dimensions. … (more)
- Is Part Of:
- Journal of endovascular therapy. Volume 23:Number 3(2016:Jun.)
- Journal:
- Journal of endovascular therapy
- Issue:
- Volume 23:Number 3(2016:Jun.)
- Issue Display:
- Volume 23, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 23
- Issue:
- 3
- Issue Sort Value:
- 2016-0023-0003-0000
- Page Start:
- 472
- Page End:
- 482
- Publication Date:
- 2016-06
- Subjects:
- aortic diameter -- imaging -- computed tomography -- descending thoracic aorta -- entry tear -- false lumen -- geometry -- lumen volume -- thoracic aortic dissection -- true lumen
Blood-vessels -- Endoscopic surgery -- Periodicals
Angioscopy -- Periodicals
Intravenous catheterization -- Periodicals
Peripheral vascular diseases -- Treatment -- Periodicals
Vascular Surgical Procedures -- Periodicals
Angioscopy -- Periodicals
Catheterization, Peripheral -- Periodicals
Peripheral Vascular Diseases -- therapy -- Periodicals
Angioscopie
Maladies vasculaires périphériques
617.413 - Journal URLs:
- http://jet.sagepub.com/ ↗
http://www.jevt.org ↗
http://www.uk.sagepub.com ↗ - DOI:
- 10.1177/1526602816642591 ↗
- Languages:
- English
- ISSNs:
- 1526-6028
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6659.xml