Intravascular Ultrasound–Derived Stent Dimensions as Predictors of Angiographic Restenosis Following Nitinol Stent Implantation in the Superficial Femoral Artery. (June 2016)
- Record Type:
- Journal Article
- Title:
- Intravascular Ultrasound–Derived Stent Dimensions as Predictors of Angiographic Restenosis Following Nitinol Stent Implantation in the Superficial Femoral Artery. (June 2016)
- Main Title:
- Intravascular Ultrasound–Derived Stent Dimensions as Predictors of Angiographic Restenosis Following Nitinol Stent Implantation in the Superficial Femoral Artery
- Authors:
- Miki, Kojiro
Fujii, Kenichi
Kawasaki, Daizo
Shibuya, Masahiko
Fukunaga, Masashi
Imanaka, Takahiro
Tamaru, Hiroto
Sumiyoshi, Akinori
Nishimura, Machiko
Horimatsu, Tetsuo
Saita, Ten
Okada, Kozo
Kimura, Takumi
Honda, Yasuhiro
Fitzgerald, Peter J.
Masuyama, Tohru
Ishihara, Masaharu - Abstract:
- Purpose: To identify intravascular ultrasound (IVUS) measurements that can predict angiographic in-stent restenosis (ISR) following nitinol stent implantation in superficial femoral artery (SFA) lesions.Methods: A retrospective review was conducted of 97 patients (mean age 72.9±8.9 years; 63 men) who underwent IVUS examination during endovascular treatment of 112 de novo SFA lesions between July 2012 and December 2014. Self-expanding bare stents were implanted in 46 lesions and paclitaxel-eluting stents in 39 lesions. Six months after stenting, follow-up angiography was conducted to assess stent patency. The primary endpoint was angiographic ISR determined by quantitative vascular angiography analysis at the 6-month follow-up. Variables associated with restenosis were sought in multivariate analysis; the results are presented as the odds ratio (OR) and 95% confidence interval (CI).Results: At follow-up, 27 (31.8%) angiographic ISR lesions were recorded. The lesions treated with uncoated stents were more prevalent in the ISR group compared with the no restenosis group (74.1% vs 44.8%, p=0.02). Lesion length was longer (154.4±79.5 vs 109.0±89.3 mm, p=0.03) and postprocedure minimum stent area (MSA) measured by IVUS was smaller (13.9±2.8 vs 16.3±1.6 mm 2, p<0.001) in the ISR group. Multivariate analysis revealed that bare stent use (OR 7.11, 95% CI 1.70 to 29.80, p<0.01) and longer lesion length (OR 1.08, 95% CI 1.01 to 1.16, p=0.04) were predictors of ISR, while increasingPurpose: To identify intravascular ultrasound (IVUS) measurements that can predict angiographic in-stent restenosis (ISR) following nitinol stent implantation in superficial femoral artery (SFA) lesions.Methods: A retrospective review was conducted of 97 patients (mean age 72.9±8.9 years; 63 men) who underwent IVUS examination during endovascular treatment of 112 de novo SFA lesions between July 2012 and December 2014. Self-expanding bare stents were implanted in 46 lesions and paclitaxel-eluting stents in 39 lesions. Six months after stenting, follow-up angiography was conducted to assess stent patency. The primary endpoint was angiographic ISR determined by quantitative vascular angiography analysis at the 6-month follow-up. Variables associated with restenosis were sought in multivariate analysis; the results are presented as the odds ratio (OR) and 95% confidence interval (CI).Results: At follow-up, 27 (31.8%) angiographic ISR lesions were recorded. The lesions treated with uncoated stents were more prevalent in the ISR group compared with the no restenosis group (74.1% vs 44.8%, p=0.02). Lesion length was longer (154.4±79.5 vs 109.0±89.3 mm, p=0.03) and postprocedure minimum stent area (MSA) measured by IVUS was smaller (13.9±2.8 vs 16.3±1.6 mm 2, p<0.001) in the ISR group. Multivariate analysis revealed that bare stent use (OR 7.11, 95% CI 1.70 to 29.80, p<0.01) and longer lesion length (OR 1.08, 95% CI 1.01 to 1.16, p=0.04) were predictors of ISR, while increasing postprocedure MSA (OR 0.58, 95% CI 0.41 to 0.82, p<0.01) was associated with lower risk of ISR. Receiver operating characteristic analysis identified a MSA of 15.5 mm 2 as the optimal cutpoint below which the incidence of restenosis increased (area under the curve 0.769).Conclusion: Postprocedure MSA can predict ISR in SFA lesions, which suggests that adequate stent enlargement during angioplasty might be required for superior patency. … (more)
- Is Part Of:
- Journal of endovascular therapy. Volume 23:Number 3(2016:Jun.)
- Journal:
- Journal of endovascular therapy
- Issue:
- Volume 23:Number 3(2016:Jun.)
- Issue Display:
- Volume 23, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 23
- Issue:
- 3
- Issue Sort Value:
- 2016-0023-0003-0000
- Page Start:
- 424
- Page End:
- 432
- Publication Date:
- 2016-06
- Subjects:
- angioplasty -- endovascular therapy -- drug-eluting stent -- in-stent restenosis -- intravascular ultrasound -- minimum stent area -- peripheral artery disease -- restenosis -- self-expanding nitinol stent -- superficial femoral artery
Blood-vessels -- Endoscopic surgery -- Periodicals
Angioscopy -- Periodicals
Intravenous catheterization -- Periodicals
Peripheral vascular diseases -- Treatment -- Periodicals
Vascular Surgical Procedures -- Periodicals
Angioscopy -- Periodicals
Catheterization, Peripheral -- Periodicals
Peripheral Vascular Diseases -- therapy -- Periodicals
Angioscopie
Maladies vasculaires périphériques
617.413 - Journal URLs:
- http://jet.sagepub.com/ ↗
http://www.jevt.org ↗
http://www.uk.sagepub.com ↗ - DOI:
- 10.1177/1526602816641669 ↗
- Languages:
- English
- ISSNs:
- 1526-6028
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6659.xml