Effect of air flow rates on concurrent supply and exhaust kitchen ventilation system. Issue 1 (February 2016)
- Record Type:
- Journal Article
- Title:
- Effect of air flow rates on concurrent supply and exhaust kitchen ventilation system. Issue 1 (February 2016)
- Main Title:
- Effect of air flow rates on concurrent supply and exhaust kitchen ventilation system
- Authors:
- Yi, Kun Woo
Kim, Young Il
Bae, Gwi-Nam - Abstract:
- Concurrent supply and exhaust ventilation (CSEV) has been developed to effectively exhaust heat and contamination from the kitchen. The objective of this research was to investigate the performance variation of this system with respect to air flow rates. CSEV system can block the contaminated air from entering the inner space by supplying fresh air horizontally in the ceilings towards the hood where the overflowed contaminated gas tends to diffuse to inner part of the room. The system captures contaminated air in an area near the ceiling and this captured air is then exhausted through the ceiling outlet. For quantitative evaluation, heat and gas capture efficiencies were defined and calculated. Experiments were conducted to compute heat and gas capture efficiencies based on the temperature and SF6 concentration data that were measured at the exhaust locations. To find optimum operation conditions for a CSEV system, numerical analysis was carried out. The numerical results were in good agreement with the experimental values. Maximum differences between the two methods are 17% for hood system and 10% for CSEV. Both heat and gas capture efficiencies would increase as exhaust flow rate of the hood increases. However, the optimum supply flow rate of ceiling nozzle was found to be 100 m 3 /h for maximum efficiency. This optimum flow rate condition would improve removing heat and contamination from the kitchen for better indoor air quality.
- Is Part Of:
- Indoor + built environment. Volume 25:Issue 1(2016)
- Journal:
- Indoor + built environment
- Issue:
- Volume 25:Issue 1(2016)
- Issue Display:
- Volume 25, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 25
- Issue:
- 1
- Issue Sort Value:
- 2016-0025-0001-0000
- Page Start:
- 180
- Page End:
- 190
- Publication Date:
- 2016-02
- Subjects:
- Kitchen ventilation -- Exhaust hood -- Concurrent supply and exhaust -- Heat capture efficiency -- Gas capture efficiency -- Coanda effect
Indoor air pollution -- Periodicals
Sick building syndrome -- Periodicals
Buildings -- Environmental engineering -- Periodicals
Environmental health -- Periodicals
613.5 - Journal URLs:
- http://ibe.sagepub.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://firstsearch.oclc.org ↗
http://www.ingenta.com/isis/browsing/AllIssues/ingenta;jsessionid=2uxluqljhi7q.crescent?journal=pubinfobike://sage/ibe ↗ - DOI:
- 10.1177/1420326X14541558 ↗
- Languages:
- English
- ISSNs:
- 1420-326X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6645.xml