Flame extension lengths beneath a confined ceiling induced by fire in a channel with longitudinal air flow. (April 2018)
- Record Type:
- Journal Article
- Title:
- Flame extension lengths beneath a confined ceiling induced by fire in a channel with longitudinal air flow. (April 2018)
- Main Title:
- Flame extension lengths beneath a confined ceiling induced by fire in a channel with longitudinal air flow
- Authors:
- Qiu, Ang
Hu, Longhua
Chen, LongFei
Carvel, Ricky O. - Abstract:
- Abstract: This paper investigates the length of flame extension for an impinging flame underneath the confined ceiling in a channel with longitudinal air flow. Previous works in this field have been primarily concerned with un-confined ceilings and no forced air flow conditions. Under longitudinal air flow conditions, the flame extension beneath the channel ceiling is non-symmetrical, that is, different in the upstream and downstream directions from the fire source. In this study, experiments were carried out with two channeled ceilings with widths of 1.5 m and 0.5 m. Square porous gas burners of different sizes were employed as the fire source, using propane as fuel, with various heat release rates and source-ceiling heights. The flame extension lengths beneath the ceiling, both upstream and downstream from the fire source, were measured. Their difference as well as their total length was quantified for different magnitudes of forced longitudinal air flow along the channel. Results show that the flame extension lengths beneath the ceiling increases with heat release rate, but decreases with source-ceiling height, channel width, burner size or longitudinal air flow speed. With a longitudinal air flow, the flame extension is longer downstream than upstream. Non-dimensional correlations are proposed for the flame extension lengths (upstream, downstream and their total length), based on the unburnt fuel distribution upstream and downstream, as well as considering airAbstract: This paper investigates the length of flame extension for an impinging flame underneath the confined ceiling in a channel with longitudinal air flow. Previous works in this field have been primarily concerned with un-confined ceilings and no forced air flow conditions. Under longitudinal air flow conditions, the flame extension beneath the channel ceiling is non-symmetrical, that is, different in the upstream and downstream directions from the fire source. In this study, experiments were carried out with two channeled ceilings with widths of 1.5 m and 0.5 m. Square porous gas burners of different sizes were employed as the fire source, using propane as fuel, with various heat release rates and source-ceiling heights. The flame extension lengths beneath the ceiling, both upstream and downstream from the fire source, were measured. Their difference as well as their total length was quantified for different magnitudes of forced longitudinal air flow along the channel. Results show that the flame extension lengths beneath the ceiling increases with heat release rate, but decreases with source-ceiling height, channel width, burner size or longitudinal air flow speed. With a longitudinal air flow, the flame extension is longer downstream than upstream. Non-dimensional correlations are proposed for the flame extension lengths (upstream, downstream and their total length), based on the unburnt fuel distribution upstream and downstream, as well as considering air entrainment of the ceiling flow, which further consumes the unburnt fuel along the ceiling. These correlations are shown to fit the data well. Highlights: Flame extension beneath a confined ceiling with longitudinal air flow. Un-symmetrical flame extension upstream and downstream with air flow. Non-dimensional correlations proposed for flame extension lengths. The proposed correlations well fit the data. … (more)
- Is Part Of:
- Fire safety journal. Volume 97(2018)
- Journal:
- Fire safety journal
- Issue:
- Volume 97(2018)
- Issue Display:
- Volume 97, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 97
- Issue:
- 2018
- Issue Sort Value:
- 2018-0097-2018-0000
- Page Start:
- 29
- Page End:
- 43
- Publication Date:
- 2018-04
- Subjects:
- Flame extension length -- Confined ceiling -- Longitudinal air flow -- Source-ceiling height -- Heat release rate -- Channel fire
Fire prevention -- Periodicals
Incendies -- Prévention -- Recherche -- Périodiques
Fire prevention -- Research
Periodicals
628.92205 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03797112 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.firesaf.2018.02.003 ↗
- Languages:
- English
- ISSNs:
- 0379-7112
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3933.285000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6625.xml