Fast and precise data acquisition for broadband microwave tomography systems. (21st August 2017)
- Record Type:
- Journal Article
- Title:
- Fast and precise data acquisition for broadband microwave tomography systems. (21st August 2017)
- Main Title:
- Fast and precise data acquisition for broadband microwave tomography systems
- Authors:
- Mallach, Malte
Musch, Thomas - Abstract:
- Abstract: Microwave imaging (MWI) is a noninvasive diagnosis method, which has been investigated for a wide range of applications. MWI techniques include radar-based approaches as well as microwave tomography (MWT). One major challenge designing broadband MWI systems is the development of a data acquisition unit that allows for fast broadband scattering parameter measurements with a high measurement precision and a high dynamic range (DR), at reasonable cost. The cost-performance criteria cannot readily be achieved using commercial, continuous wave (CW) vector network analyzers (VNA) or pulse-based systems. Therefore, in this paper we propose a data acquisition unit, based on the well-known method of frequency modulated continuous wave (FMCW) network analysis. It offers fast scattering parameter measurements without compromising the measurement precision and the DR, and is particularly advantageous for MWI systems requiring a high number of frequency samples. A 2-port metadyne prototype electronics with low hardware complexity was developed, which allows very fast, precise, and accurate reflection and transmission measurements in the frequency range from 0.5 GHz to 5.5 GHz. To the best of the authors' knowledge, a system with combined performance in terms of bandwidth, sweep time (1 ms), DR (80 dB) and maximum signal-to-noise-and-spurious ratio (65 dB) has not previously been reported. The design, the calibration, and the characterization of the prototype electronics areAbstract: Microwave imaging (MWI) is a noninvasive diagnosis method, which has been investigated for a wide range of applications. MWI techniques include radar-based approaches as well as microwave tomography (MWT). One major challenge designing broadband MWI systems is the development of a data acquisition unit that allows for fast broadband scattering parameter measurements with a high measurement precision and a high dynamic range (DR), at reasonable cost. The cost-performance criteria cannot readily be achieved using commercial, continuous wave (CW) vector network analyzers (VNA) or pulse-based systems. Therefore, in this paper we propose a data acquisition unit, based on the well-known method of frequency modulated continuous wave (FMCW) network analysis. It offers fast scattering parameter measurements without compromising the measurement precision and the DR, and is particularly advantageous for MWI systems requiring a high number of frequency samples. A 2-port metadyne prototype electronics with low hardware complexity was developed, which allows very fast, precise, and accurate reflection and transmission measurements in the frequency range from 0.5 GHz to 5.5 GHz. To the best of the authors' knowledge, a system with combined performance in terms of bandwidth, sweep time (1 ms), DR (80 dB) and maximum signal-to-noise-and-spurious ratio (65 dB) has not previously been reported. The design, the calibration, and the characterization of the prototype electronics are described in detail, and the measurement results are compared to those obtained with commercial high-end CW VNA. The advantages and limitations of the metadyne FMCW technique compared to the heterodyne CW technique are discussed. The applicability of the prototype electronics and the described calibration technique for microwave imaging has been demonstrated based on measurements using an 8-port MWT sensor and a switching matrix. … (more)
- Is Part Of:
- Measurement science & technology. Volume 28:Number 9(2017:Sep.)
- Journal:
- Measurement science & technology
- Issue:
- Volume 28:Number 9(2017:Sep.)
- Issue Display:
- Volume 28, Issue 9 (2017)
- Year:
- 2017
- Volume:
- 28
- Issue:
- 9
- Issue Sort Value:
- 2017-0028-0009-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-08-21
- Subjects:
- scattering parameter -- vector network analysis -- linear frequency ramp -- frequency modulated continuous wave -- microwave tomography -- microwave imaging
Physical measurements -- Periodicals
Scientific apparatus and instruments -- Periodicals
Equipment and Supplies -- Periodicals
Science -- instrumentation -- Periodicals
Technology -- instrumentation -- Periodicals
Mesures physiques -- Périodiques
Physical measurements
Scientific apparatus and instruments
Periodicals
502.87 - Journal URLs:
- http://iopscience.iop.org/0957-0233/ ↗
http://www.iop.org/Journals/mt ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1361-6501/aa6a86 ↗
- Languages:
- English
- ISSNs:
- 0957-0233
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 6629.xml