A simplified edge illumination set-up for quantitative phase contrast mammography with synchrotron radiation at clinical doses. (9th January 2015)
- Record Type:
- Journal Article
- Title:
- A simplified edge illumination set-up for quantitative phase contrast mammography with synchrotron radiation at clinical doses. (9th January 2015)
- Main Title:
- A simplified edge illumination set-up for quantitative phase contrast mammography with synchrotron radiation at clinical doses
- Authors:
- Longo, Mariaconcetta
Rigon, Luigi
Lopez, Frances C M
Chen, Rongchang
Dreossi, Diego
Zanconati, Fabrizio
Longo, Renata - Abstract:
- Abstract: This work presents the first study of x-ray phase contrast imaging based on a simple implementation of the edge illumination method (EIXPCi) in the field of mammography with synchrotron radiation. A simplified EIXPCi set-up was utilized to study a possible application in mammography at clinical doses. Moreover, through a novel algorithm capable of separating and quantifying absorption and phase perturbations of images acquired in EIXPCi modality, it is possible to extract quantitative information on breast images, allowing an accurate tissue identification. The study was carried out at the SYRMEP beamline of Elettra synchrotron radiation facility (Trieste, Italy), where a mastectomy specimen was investigated with the EIXPCi technique. The sample was exposed at three different energies suitable for mammography with synchrotron radiation in order to test the validity of the novel algorithm in extracting values of linear attenuation coefficients integrated over the sample thickness. It is demonstrated that the quantitative data are in good agreement with the theoretical values of linear attenuation coefficients calculated on the hypothesis of the breast with a given composition. The results are promising and encourage the current efforts to apply the method in mammography with synchrotron radiation.
- Is Part Of:
- Physics in medicine & biology. Volume 60:Number 3(2015:Feb.)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 60:Number 3(2015:Feb.)
- Issue Display:
- Volume 60, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 60
- Issue:
- 3
- Issue Sort Value:
- 2015-0060-0003-0000
- Page Start:
- N21
- Page End:
- N34
- Publication Date:
- 2015-01-09
- Subjects:
- phase contrast -- mammography -- synchrotron radiation -- phase retrieval -- edge illumination
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/0031-9155/60/3/N21 ↗
- Languages:
- English
- ISSNs:
- 0031-9155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 6606.xml