Contouring variability of human- and deformable-generated contours in radiotherapy for prostate cancer. (19th May 2015)
- Record Type:
- Journal Article
- Title:
- Contouring variability of human- and deformable-generated contours in radiotherapy for prostate cancer. (19th May 2015)
- Main Title:
- Contouring variability of human- and deformable-generated contours in radiotherapy for prostate cancer
- Authors:
- Gardner, Stephen J
Wen, Ning
Kim, Jinkoo
Liu, Chang
Pradhan, Deepak
Aref, Ibrahim
Cattaneo, Richard
Vance, Sean
Movsas, Benjamin
Chetty, Indrin J
Elshaikh, Mohamed A - Abstract:
- Abstract: This study was designed to evaluate contouring variability of human-and deformable-generated contours on planning CT (PCT) and CBCT for ten patients with low-or intermediate-risk prostate cancer. For each patient in this study, five radiation oncologists contoured the prostate, bladder, and rectum, on one PCT dataset and five CBCT datasets. Consensus contours were generated using the STAPLE method in the CERR software package. Observer contours were compared to consensus contour, and contour metrics (Dice coefficient, Hausdorff distance, Contour Distance, Center-of-Mass [COM] Deviation) were calculated. In addition, the first day CBCT was registered to subsequent CBCT fractions (CBCT n : CBCT2–CBCT5) via B-spline Deformable Image Registration (DIR). Contours were transferred from CBCT1 to CBCT n via the deformation field, and contour metrics were calculated through comparison with consensus contours generated from human contour set. The average contour metrics for prostate contours on PCT and CBCT were as follows: Dice coefficient—0.892 (PCT), 0.872 (CBCT-Human), 0.824 (CBCT-Deformed); Hausdorff distance—4.75 mm (PCT), 5.22 mm (CBCT-Human), 5.94 mm (CBCT-Deformed); Contour Distance (overall contour)—1.41 mm (PCT), 1.66 mm (CBCT-Human), 2.30 mm (CBCT-Deformed); COM Deviation—2.01 mm (PCT), 2.78 mm (CBCT-Human), 3.45 mm (CBCT-Deformed). For human contours on PCT and CBCT, the difference in average Dice coefficient between PCT and CBCT (approx. 2%) and HausdorffAbstract: This study was designed to evaluate contouring variability of human-and deformable-generated contours on planning CT (PCT) and CBCT for ten patients with low-or intermediate-risk prostate cancer. For each patient in this study, five radiation oncologists contoured the prostate, bladder, and rectum, on one PCT dataset and five CBCT datasets. Consensus contours were generated using the STAPLE method in the CERR software package. Observer contours were compared to consensus contour, and contour metrics (Dice coefficient, Hausdorff distance, Contour Distance, Center-of-Mass [COM] Deviation) were calculated. In addition, the first day CBCT was registered to subsequent CBCT fractions (CBCT n : CBCT2–CBCT5) via B-spline Deformable Image Registration (DIR). Contours were transferred from CBCT1 to CBCT n via the deformation field, and contour metrics were calculated through comparison with consensus contours generated from human contour set. The average contour metrics for prostate contours on PCT and CBCT were as follows: Dice coefficient—0.892 (PCT), 0.872 (CBCT-Human), 0.824 (CBCT-Deformed); Hausdorff distance—4.75 mm (PCT), 5.22 mm (CBCT-Human), 5.94 mm (CBCT-Deformed); Contour Distance (overall contour)—1.41 mm (PCT), 1.66 mm (CBCT-Human), 2.30 mm (CBCT-Deformed); COM Deviation—2.01 mm (PCT), 2.78 mm (CBCT-Human), 3.45 mm (CBCT-Deformed). For human contours on PCT and CBCT, the difference in average Dice coefficient between PCT and CBCT (approx. 2%) and Hausdorff distance (approx. 0.5 mm) was small compared to the variation between observers for each patient (standard deviation in Dice coefficient of 5% and Hausdorff distance of 2.0 mm). However, additional contouring variation was found for the deformable-generated contours (approximately 5.0% decrease in Dice coefficient and 0.7 mm increase in Hausdorff distance relative to human-generated contours on CBCT). Though deformable contours provide a reasonable starting point for contouring on CBCT, we conclude that contours generated with B-Spline DIR require physician review and editing if they are to be used in the clinic. … (more)
- Is Part Of:
- Physics in medicine & biology. Volume 60:Number 11(2015:Jun.)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 60:Number 11(2015:Jun.)
- Issue Display:
- Volume 60, Issue 11 (2015)
- Year:
- 2015
- Volume:
- 60
- Issue:
- 11
- Issue Sort Value:
- 2015-0060-0011-0000
- Page Start:
- 4429
- Page End:
- 4447
- Publication Date:
- 2015-05-19
- Subjects:
- prostate cancer -- contouring variation -- adaptive radiotherapy -- cone-beam CT -- deformable registration
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/0031-9155/60/11/4429 ↗
- Languages:
- English
- ISSNs:
- 0031-9155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 6604.xml