Environmental contamination by cyclophosphamide preparation: Comparison of conventional manual production in biological safety cabinet and robot-assisted production by APOTECAchemo. (February 2016)
- Record Type:
- Journal Article
- Title:
- Environmental contamination by cyclophosphamide preparation: Comparison of conventional manual production in biological safety cabinet and robot-assisted production by APOTECAchemo. (February 2016)
- Main Title:
- Environmental contamination by cyclophosphamide preparation: Comparison of conventional manual production in biological safety cabinet and robot-assisted production by APOTECAchemo
- Authors:
- Schierl, Rudolf
Masini, Carla
Groeneveld, Svenja
Fischer, Elke
Böhlandt, Antje
Rosini, Valeria
Paolucci, Demis - Abstract:
- Objectives: The aim of this study was to compare environmental contamination of cyclophosphamide (CP) during 1 week of drug compounding by conventional manual procedure in a biological safety cabinet (BSC) with laminar airflow and a new robotic drug preparation system (APOTECAchemo). Methods: During four consecutive days, similar numbers of infusion bags with cyclophosphamide were prepared with both techniques in a cross-over design. Wipe samples (49 for BSC, 50 for APOTECAchemo) were taken at several locations (gloves, infusion bags, trays, BSC-benches, floor) in the pharmacy and analyzed for CP concentrations by GC-MSMS (LOD 0.2 ng/sample). Results: The detection rate was 70% in the BSC versus 15% in APOTECAchemo. During manual preparation of admixtures using BSC contamination with CP was below 0.001 ng/cm 2 at most locations, but significant on gloves (0.0004–0.0967 ng/cm 2 ) and the majority (70%) of infusion bags (<0.0004–2.89 ng/cm 2 ). During robotic preparation by APOTECAchemo, gloves (1 of 8: 0.0007 ng/cm 2 ) and infusion bags (3 of 20: 0.0005, 0.0019, 0.0094 ng/cm 2 ) were considerably less contaminated. Residual contamination was found on the surfaces under the dosing device in the compounding area (0.0293–0.1603 ng/cm 2 ) inside the robotic system. Conclusions: Compared to outcomes of other studies, our results underline good manufacturing procedures in this pharmacy with low contamination for both techniques (BSC and APOTECAchemo). Comparison of both preparationObjectives: The aim of this study was to compare environmental contamination of cyclophosphamide (CP) during 1 week of drug compounding by conventional manual procedure in a biological safety cabinet (BSC) with laminar airflow and a new robotic drug preparation system (APOTECAchemo). Methods: During four consecutive days, similar numbers of infusion bags with cyclophosphamide were prepared with both techniques in a cross-over design. Wipe samples (49 for BSC, 50 for APOTECAchemo) were taken at several locations (gloves, infusion bags, trays, BSC-benches, floor) in the pharmacy and analyzed for CP concentrations by GC-MSMS (LOD 0.2 ng/sample). Results: The detection rate was 70% in the BSC versus 15% in APOTECAchemo. During manual preparation of admixtures using BSC contamination with CP was below 0.001 ng/cm 2 at most locations, but significant on gloves (0.0004–0.0967 ng/cm 2 ) and the majority (70%) of infusion bags (<0.0004–2.89 ng/cm 2 ). During robotic preparation by APOTECAchemo, gloves (1 of 8: 0.0007 ng/cm 2 ) and infusion bags (3 of 20: 0.0005, 0.0019, 0.0094 ng/cm 2 ) were considerably less contaminated. Residual contamination was found on the surfaces under the dosing device in the compounding area (0.0293–0.1603 ng/cm 2 ) inside the robotic system. Conclusions: Compared to outcomes of other studies, our results underline good manufacturing procedures in this pharmacy with low contamination for both techniques (BSC and APOTECAchemo). Comparison of both preparation procedures validated that contamination of infusion bags was much lower by using the robotic system. … (more)
- Is Part Of:
- Journal of oncology pharmacy practice. Volume 22:Number 1(2016:Mar.)
- Journal:
- Journal of oncology pharmacy practice
- Issue:
- Volume 22:Number 1(2016:Mar.)
- Issue Display:
- Volume 22, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 22
- Issue:
- 1
- Issue Sort Value:
- 2016-0022-0001-0000
- Page Start:
- 37
- Page End:
- 45
- Publication Date:
- 2016-02
- Subjects:
- Biological safety cabinet -- robotic system -- cytotoxic drugs -- cyclophosphamide -- wipe sampling
Cancer -- Chemotherapy -- Periodicals
Clinical pharmacology -- Periodicals
616.994061 - Journal URLs:
- http://opp.sagepub.com/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/1078155214551316 ↗
- Languages:
- English
- ISSNs:
- 1078-1552
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6622.xml