Multicenter in vitro thromboelastography and thromboelastometry standardization. Issue 3 (31st March 2018)
- Record Type:
- Journal Article
- Title:
- Multicenter in vitro thromboelastography and thromboelastometry standardization. Issue 3 (31st March 2018)
- Main Title:
- Multicenter in vitro thromboelastography and thromboelastometry standardization
- Authors:
- Goggs, Robert
Borrelli, Antonio
Brainard, Benjamin M.
Chan, Daniel L.
de Laforcade, Armelle
Goy‐Thollot, Isabelle
Jandrey, Karl E.
Kristensen, Annemarie T.
Kutter, Annette
Marschner, Clara B.
Rannou, Benoît
Sigrist, Nadja
Wagg, Catherine - Abstract:
- Abstract: Objective: To establish and compare the repeatability and reproducibility of activated thromboelastography (TEG) and thromboelastometry (ROTEM) assays. Design: Multicenter in vitro test standardization. Setting: Veterinary academic centers. Animals: Test samples were obtained from normal, healthy dogs. Sixty identical 5 mL aliquots of canine platelet‐rich plasma collected by apheresis, frozen in 6% dimethyl sulfoxide, were tested initially. Sixty identical 6 mL aliquots of canine fresh frozen plasma with admixed cryoprecipitate were subsequently evaluated. Interventions: None. Measurements and Main Results: Frozen study samples, quality controls, reagents, and consumables were distributed to participating centers (7 TEG and 3 ROTEM). TEG centers analyzed study samples with kaolin and tissue factor activated assays; ROTEM centers ran proprietary ellagic acid activated and tissue factor activated assays. All machines underwent quality control prior to sample analysis. Within‐ and between‐center coefficients of variation (CVs) were calculated and compared using Mann–Whitney tests and calculation of intraclass correlation coefficients. Within and between centers, individual parameters for both TEG and ROTEM assays were comparable. Both within‐center and between‐center CVs varied markedly (0.7–120.5% and 1.4–116.5%, respectively) with assay type, instrument, and parameter. CVs for equivalent parameters were not significantly different between the 2 platforms. IntraclassAbstract: Objective: To establish and compare the repeatability and reproducibility of activated thromboelastography (TEG) and thromboelastometry (ROTEM) assays. Design: Multicenter in vitro test standardization. Setting: Veterinary academic centers. Animals: Test samples were obtained from normal, healthy dogs. Sixty identical 5 mL aliquots of canine platelet‐rich plasma collected by apheresis, frozen in 6% dimethyl sulfoxide, were tested initially. Sixty identical 6 mL aliquots of canine fresh frozen plasma with admixed cryoprecipitate were subsequently evaluated. Interventions: None. Measurements and Main Results: Frozen study samples, quality controls, reagents, and consumables were distributed to participating centers (7 TEG and 3 ROTEM). TEG centers analyzed study samples with kaolin and tissue factor activated assays; ROTEM centers ran proprietary ellagic acid activated and tissue factor activated assays. All machines underwent quality control prior to sample analysis. Within‐ and between‐center coefficients of variation (CVs) were calculated and compared using Mann–Whitney tests and calculation of intraclass correlation coefficients. Within and between centers, individual parameters for both TEG and ROTEM assays were comparable. Both within‐center and between‐center CVs varied markedly (0.7–120.5% and 1.4–116.5%, respectively) with assay type, instrument, and parameter. CVs for equivalent parameters were not significantly different between the 2 platforms. Intraclass correlation coefficients suggested moderate agreement between centers. In general, individual parameter CVs for platelet‐rich plasma samples were lower in TEG centers, while CVs for canine fresh frozen plasma with admixed cryoprecipitate samples were lower in ROTEM centers. Conclusions: More variation within and between centers was identified than anticipated, but some parameters such as alpha angle were repeatable and reproducible. Sample types for future multicenter standardization efforts will require further optimization and may need to be adapted separately to each platform. Individual centers using viscoelastic tests for evaluation and management of clinical patients should take steps to minimize preanalytical and analytical sources of variation. … (more)
- Is Part Of:
- Journal of veterinary emergency and critical care. Volume 28:Issue 3(2018)
- Journal:
- Journal of veterinary emergency and critical care
- Issue:
- Volume 28:Issue 3(2018)
- Issue Display:
- Volume 28, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 28
- Issue:
- 3
- Issue Sort Value:
- 2018-0028-0003-0000
- Page Start:
- 201
- Page End:
- 212
- Publication Date:
- 2018-03-31
- Subjects:
- canine -- dog -- repeatability -- reproducibility -- thromboelastography -- thromboelastometry
Veterinary emergencies -- Periodicals
Veterinary critical care -- Periodicals
636.089 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1476-4431 ↗
http://www.blackwell-synergy.com/rd.asp?goto=journal&code=vec ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/vec.12710 ↗
- Languages:
- English
- ISSNs:
- 1479-3261
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5072.362000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 6629.xml