The consistency between measurements of the femoral neck anteversion angle in DDH on three-dimensional CT and MRI. (June 2016)
- Record Type:
- Journal Article
- Title:
- The consistency between measurements of the femoral neck anteversion angle in DDH on three-dimensional CT and MRI. (June 2016)
- Main Title:
- The consistency between measurements of the femoral neck anteversion angle in DDH on three-dimensional CT and MRI
- Authors:
- Mao, Cunhua
Liang, Yanchen
Ding, Chengzong
Guo, Lingfei
Wang, Yanbing
Zeng, Qingjuan
Wang, Guangbin - Abstract:
- Background: Three-dimensional computed tomography (3D CT) has been regarded by some investigators as the gold standard for measurements of the femoral neck anteversion angle (FNA) in developmental dysplasia of the hip (DDH), although a simple and reliable imaging method using a non-ionizing technique is needed. Purpose: To determine the consistency between measurements of the FNA in DDH using 3D CT and magnetic resonance imaging (MRI) and to estimate the precision, reliability, and reproducibility of MRI for the measurement of the FNA and assess whether MRI could replace 3D CT. Material and Methods: 3D CT and MRI were used to measure the FNA in 22 patients, including 18 girls and four boys, with a mean age of 3 years (age range, 1–7 years). All of the measurements were performed independently by two radiologists at different times. This exercise was repeated 2 weeks later by one of the radiologists. Results: High consistency was found between the MRI and 3D CT measurements (intraclass correlation coefficient [ICC] of 0.906, P < 0.05). The mean inter-observer and intra-observer agreements were high for MRI (ICC = 0.948 and 0.964, respectively, P < 0.05 for both) and for 3D CT (ICC = 0.942 and 0.966, respectively, P < 0.05 for both). Conclusion: Compared with 3D CT, MRI provided a precise, reliable and reproducible method of measuring the FNA in DDH. MRI is recommended as an appropriate technique for measurement of the FNA in DDH, and this approach could replace 3D CTBackground: Three-dimensional computed tomography (3D CT) has been regarded by some investigators as the gold standard for measurements of the femoral neck anteversion angle (FNA) in developmental dysplasia of the hip (DDH), although a simple and reliable imaging method using a non-ionizing technique is needed. Purpose: To determine the consistency between measurements of the FNA in DDH using 3D CT and magnetic resonance imaging (MRI) and to estimate the precision, reliability, and reproducibility of MRI for the measurement of the FNA and assess whether MRI could replace 3D CT. Material and Methods: 3D CT and MRI were used to measure the FNA in 22 patients, including 18 girls and four boys, with a mean age of 3 years (age range, 1–7 years). All of the measurements were performed independently by two radiologists at different times. This exercise was repeated 2 weeks later by one of the radiologists. Results: High consistency was found between the MRI and 3D CT measurements (intraclass correlation coefficient [ICC] of 0.906, P < 0.05). The mean inter-observer and intra-observer agreements were high for MRI (ICC = 0.948 and 0.964, respectively, P < 0.05 for both) and for 3D CT (ICC = 0.942 and 0.966, respectively, P < 0.05 for both). Conclusion: Compared with 3D CT, MRI provided a precise, reliable and reproducible method of measuring the FNA in DDH. MRI is recommended as an appropriate technique for measurement of the FNA in DDH, and this approach could replace 3D CT because it delivers no ionizing radiation and offers a better display of soft tissue pathological changes. … (more)
- Is Part Of:
- Acta radiologica. Volume 57:Number 6(2016:Jun.)
- Journal:
- Acta radiologica
- Issue:
- Volume 57:Number 6(2016:Jun.)
- Issue Display:
- Volume 57, Issue 6 (2016)
- Year:
- 2016
- Volume:
- 57
- Issue:
- 6
- Issue Sort Value:
- 2016-0057-0006-0000
- Page Start:
- 716
- Page End:
- 720
- Publication Date:
- 2016-06
- Subjects:
- Computed tomography (CT) -- magnetic resonance imaging (MRI) -- femoral neck anteversion
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1177/0284185115603244 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6598.xml