A hybrid phantom Monte Carlo-based method for historical reconstruction of organ doses in patients treated with cobalt-60 for Hodgkin's lymphoma. (17th July 2017)
- Record Type:
- Journal Article
- Title:
- A hybrid phantom Monte Carlo-based method for historical reconstruction of organ doses in patients treated with cobalt-60 for Hodgkin's lymphoma. (17th July 2017)
- Main Title:
- A hybrid phantom Monte Carlo-based method for historical reconstruction of organ doses in patients treated with cobalt-60 for Hodgkin's lymphoma
- Authors:
- Petroccia, Heather
Mendenhall, Nancy
Liu, Chihray
Hammer, Clifford
Culberson, Wesley
Thar, Tim
Mitchell, Tom
Li, Zuofeng
Bolch, Wesley - Abstract:
- Abstract: Historical radiotherapy treatment plans lack 3D images sets required for estimating mean organ doses to patients. Alternatively, Monte Carlo-based models of radiotherapy devices coupled with whole-body computational phantoms can permit estimates of historical in-field and out-of-field organ doses as needed for studies associating radiation exposure and late tissue toxicities. In recreating historical patient treatments with 60 Co based systems, the major components to be modeled include the source capsule, surrounding shielding layers, collimators (both fixed and adjustable), and trimmers as needed to vary field size. In this study, a computational model and experimental validation of the Theratron T-1000 are presented. Model validation is based upon in-field commissioning data collected at the University of Florida, published out-of-field data from the British Journal of Radiology (BJR) Supplement 25, and out-of-field measurements performed at the University of Wisconsin's Accredited Dosimetry Calibration Laboratory (UWADCL). The computational model of the Theratron T-1000 agrees with central axis percentage depth dose data to within 2% for 6 × 6 to 30 × 30 cm 2 fields. Out-of-field doses were found to vary between 0.6% to 2.4% of central axis dose at 10 cm from field edge and 0.42% to 0.97% of central axis dose at 20 cm from the field edge, all at 5 cm depth. Absolute and relative differences between computed and measured out-of-field doses variedAbstract: Historical radiotherapy treatment plans lack 3D images sets required for estimating mean organ doses to patients. Alternatively, Monte Carlo-based models of radiotherapy devices coupled with whole-body computational phantoms can permit estimates of historical in-field and out-of-field organ doses as needed for studies associating radiation exposure and late tissue toxicities. In recreating historical patient treatments with 60 Co based systems, the major components to be modeled include the source capsule, surrounding shielding layers, collimators (both fixed and adjustable), and trimmers as needed to vary field size. In this study, a computational model and experimental validation of the Theratron T-1000 are presented. Model validation is based upon in-field commissioning data collected at the University of Florida, published out-of-field data from the British Journal of Radiology (BJR) Supplement 25, and out-of-field measurements performed at the University of Wisconsin's Accredited Dosimetry Calibration Laboratory (UWADCL). The computational model of the Theratron T-1000 agrees with central axis percentage depth dose data to within 2% for 6 × 6 to 30 × 30 cm 2 fields. Out-of-field doses were found to vary between 0.6% to 2.4% of central axis dose at 10 cm from field edge and 0.42% to 0.97% of central axis dose at 20 cm from the field edge, all at 5 cm depth. Absolute and relative differences between computed and measured out-of-field doses varied between ±2.5% and ±100%, respectively, at distances up to 60 cm from the central axis. The source-term model was subsequently combined with patient-morphometry matched computational hybrid phantoms as a method for estimating in-field and out-of-field organ doses for patients treated for Hodgkin's Lymphoma. By changing field size and position, and adding patient-specific field shaping blocks, more complex historical treatment set-ups can be to recreated, particularly those for which 2D or 3D image sets are unavailable. … (more)
- Is Part Of:
- Physics in medicine & biology. Volume 62:Number 15(2017:Aug.)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 62:Number 15(2017:Aug.)
- Issue Display:
- Volume 62, Issue 15 (2017)
- Year:
- 2017
- Volume:
- 62
- Issue:
- 15
- Issue Sort Value:
- 2017-0062-0015-0000
- Page Start:
- 6261
- Page End:
- 6289
- Publication Date:
- 2017-07-17
- Subjects:
- Monte Carlo -- organ dosimetry -- dose reconstruction -- Hodgkin's lymphoma -- computational phantom
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/1361-6560/aa7c2f ↗