A Review on the Hemodialysis Reliable Outflow (HeRO) Graft for Haemodialysis Vascular Access. Issue 1 (July 2015)
- Record Type:
- Journal Article
- Title:
- A Review on the Hemodialysis Reliable Outflow (HeRO) Graft for Haemodialysis Vascular Access. Issue 1 (July 2015)
- Main Title:
- A Review on the Hemodialysis Reliable Outflow (HeRO) Graft for Haemodialysis Vascular Access
- Authors:
- Al Shakarchi, J.
Houston, J.G.
Jones, R.G.
Inston, N. - Abstract:
- Abstract : Objectives: With improved dialysis survival there are increasing numbers of patients who have exhausted definitive access options due to central venous stenosis and are maintaining dialysis on a central venous catheter. The Hemodialysis Reliable Outflow (HeRO) allows an alternative by providing a definitive access solution. The aim of this study is to systematically review the published outcomes of the HeRO graft and discuss the role in complex haemodialysis patients. Methods: Electronic databases were searched for studies assessing the use of the HeRO graft for dialysis in accordance with PRISMA published up to December 31 2014. The primary outcomes for this study were 1-year primary and secondary patency rates. Secondary outcomes were rates of dialysis access associated steal syndrome, HeRO-related bacteraemia rates and rates of interventions. Results: Following strict inclusion/exclusion criteria, eight studies including 409 patients were included in our review. Primary and secondary pooled patency rates in this complex cohort of dialysis patients were found to be 21.9% (9.6–37.2%) and 59.4% (39.4–78%). The rate of dialysis access associated steal syndrome was low at 6.3% (1–14.7%) as was the range of HeRO-related bacteraemia (0.13–0.7 events per 1000 days). Conclusions: This literature review shows that the HeRO graft is an acceptable option for complex dialysis patients who are catheter dependent. Owing to device availability, published data are predominantlyAbstract : Objectives: With improved dialysis survival there are increasing numbers of patients who have exhausted definitive access options due to central venous stenosis and are maintaining dialysis on a central venous catheter. The Hemodialysis Reliable Outflow (HeRO) allows an alternative by providing a definitive access solution. The aim of this study is to systematically review the published outcomes of the HeRO graft and discuss the role in complex haemodialysis patients. Methods: Electronic databases were searched for studies assessing the use of the HeRO graft for dialysis in accordance with PRISMA published up to December 31 2014. The primary outcomes for this study were 1-year primary and secondary patency rates. Secondary outcomes were rates of dialysis access associated steal syndrome, HeRO-related bacteraemia rates and rates of interventions. Results: Following strict inclusion/exclusion criteria, eight studies including 409 patients were included in our review. Primary and secondary pooled patency rates in this complex cohort of dialysis patients were found to be 21.9% (9.6–37.2%) and 59.4% (39.4–78%). The rate of dialysis access associated steal syndrome was low at 6.3% (1–14.7%) as was the range of HeRO-related bacteraemia (0.13–0.7 events per 1000 days). Conclusions: This literature review shows that the HeRO graft is an acceptable option for complex dialysis patients who are catheter dependent. Owing to device availability, published data are predominantly North American and further longer-term studies in other populations may be necessary. In this challenging patient group, randomized controlled trials are required to allow comparisons with alternative access options. … (more)
- Is Part Of:
- European journal of vascular and endovascular surgery. Volume 50:Issue 1(2015:Jul.)
- Journal:
- European journal of vascular and endovascular surgery
- Issue:
- Volume 50:Issue 1(2015:Jul.)
- Issue Display:
- Volume 50, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 50
- Issue:
- 1
- Issue Sort Value:
- 2015-0050-0001-0000
- Page Start:
- 108
- Page End:
- 113
- Publication Date:
- 2015-07
- Subjects:
- Graft -- Haemodialysis -- HeRO -- Outflow -- Catheter
Blood-vessels -- Endoscopic surgery -- Periodicals
Blood-vessels -- Surgery -- Periodicals
Vascular Surgical Procedures -- Periodicals
Vascular Surgical Procedures -- methods -- Periodicals
Vaisseaux sanguins -- Chirurgie -- Périodiques
Vaisseaux sanguins -- Chirurgie endoscopique -- Périodiques
Blood-vessels -- Endoscopic surgery
Blood-vessels -- Surgery
Endoscopy
Electronic journals
Periodicals
Electronic journals
617.413005 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=1078-5884;screen=info;ECOIP ↗
http://www.harcourt-international.com/journals/ejvs/ ↗
http://www.harcourt-international.com/journals/ejvx/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10785884 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/10785884 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejvs.2015.03.059 ↗
- Languages:
- English
- ISSNs:
- 1078-5884
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.747280
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 6587.xml