Hypoglycemia in Type 2 Diabetes - More Common Than You Think: A Continuous Glucose Monitoring Study. (27th April 2015)
- Record Type:
- Journal Article
- Title:
- Hypoglycemia in Type 2 Diabetes - More Common Than You Think: A Continuous Glucose Monitoring Study. (27th April 2015)
- Main Title:
- Hypoglycemia in Type 2 Diabetes - More Common Than You Think
- Authors:
- Gehlaut, Richa Redhu
Dogbey, Godwin Y.
Schwartz, Frank L.
Marling, Cynthia R.
Shubrook, Jay H. - Abstract:
- Background: Hypoglycemia is often the limiting factor for intensive glucose control in diabetes management, however its actual prevalence in type 2 diabetes (T2DM) is not well documented. Methodology: A total of 108 patients with T2DM wore a continuous glucose monitoring system (CGMS) for 5 days. Rates and patterns of hypoglycemia and glycemic variability (GV) were calculated. Patient and medication factors were correlated with rates, timing, and severity of hypoglycemia. Results: Of the patients, 49.1% had at least 1 hypoglycemic episode (mean 1.74 episodes/patient/ 5 days of CGMS) and 75% of those patients experienced at least 1 asymptomatic hypoglycemic episode. There was no significant difference in the frequency of daytime versus nocturnal hypoglycemia. Hypoglycemia was more frequent in individuals on insulin (alone or in combination) ( P = .02) and those on oral hypoglycemic agents ( P < .001) compared to noninsulin secretagogues. CGMS analysis resulted in treatment modifications in 64% of the patients. T2DM patients on insulin exhibited higher glycemic variability (GV) scores (2.3 ± 0.6) as compared to those on oral medications (1.8 ± 0.7, P = .017). Conclusions: CGMS can provide rich data that show glucose excursions in diabetes patients throughout the day. Consequently, unwarranted onset of hypo- and hyperglycemic events can be detected, intervened, and prevented by using CGMS. Hypoglycemia was frequently unrecognized by the patients in this study (75%), whichBackground: Hypoglycemia is often the limiting factor for intensive glucose control in diabetes management, however its actual prevalence in type 2 diabetes (T2DM) is not well documented. Methodology: A total of 108 patients with T2DM wore a continuous glucose monitoring system (CGMS) for 5 days. Rates and patterns of hypoglycemia and glycemic variability (GV) were calculated. Patient and medication factors were correlated with rates, timing, and severity of hypoglycemia. Results: Of the patients, 49.1% had at least 1 hypoglycemic episode (mean 1.74 episodes/patient/ 5 days of CGMS) and 75% of those patients experienced at least 1 asymptomatic hypoglycemic episode. There was no significant difference in the frequency of daytime versus nocturnal hypoglycemia. Hypoglycemia was more frequent in individuals on insulin (alone or in combination) ( P = .02) and those on oral hypoglycemic agents ( P < .001) compared to noninsulin secretagogues. CGMS analysis resulted in treatment modifications in 64% of the patients. T2DM patients on insulin exhibited higher glycemic variability (GV) scores (2.3 ± 0.6) as compared to those on oral medications (1.8 ± 0.7, P = .017). Conclusions: CGMS can provide rich data that show glucose excursions in diabetes patients throughout the day. Consequently, unwarranted onset of hypo- and hyperglycemic events can be detected, intervened, and prevented by using CGMS. Hypoglycemia was frequently unrecognized by the patients in this study (75%), which increases their potential risk of significant adverse events. Incorporation of CGMS into the routine management of T2DM would increase the detection and self-awareness of hypoglycemia resulting in safer and potentially better overall control. … (more)
- Is Part Of:
- Journal of diabetes science and technology. Volume 9:Number 5(2015:Sept.)
- Journal:
- Journal of diabetes science and technology
- Issue:
- Volume 9:Number 5(2015:Sept.)
- Issue Display:
- Volume 9, Issue 5 (2015)
- Year:
- 2015
- Volume:
- 9
- Issue:
- 5
- Issue Sort Value:
- 2015-0009-0005-0000
- Page Start:
- 999
- Page End:
- 1005
- Publication Date:
- 2015-04-27
- Subjects:
- continuous glucose monitoring system -- glycemic variability -- hypoglycemia -- hypoglycemia unawareness -- self-glucose monitoring -- type 2 diabetes
Diabetes -- Periodicals
Medical technology -- Periodicals
Diabetes Mellitus -- Periodicals
616.462005 - Journal URLs:
- http://ejournals.ebsco.com/direct.asp?JournalID=712321 ↗
http://www.jodsat.org/about.html ↗
http://online.sagepub.com/ ↗ - DOI:
- 10.1177/1932296815581052 ↗
- Languages:
- English
- ISSNs:
- 1932-2968
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6583.xml