Time Lag of Glucose From Intravascular to Interstitial Compartment in Type 1 Diabetes. (10th October 2014)
- Record Type:
- Journal Article
- Title:
- Time Lag of Glucose From Intravascular to Interstitial Compartment in Type 1 Diabetes. (10th October 2014)
- Main Title:
- Time Lag of Glucose From Intravascular to Interstitial Compartment in Type 1 Diabetes
- Authors:
- Basu, Ananda
Dube, Simmi
Veettil, Sona
Slama, Michael
Kudva, Yogish C.
Peyser, Thomas
Carter, Rickey E.
Cobelli, Claudio
Basu, Rita - Abstract:
- Background and Objective: The premise of effective closed-loop insulin therapy for type 1 diabetes (T1D) relies on the accuracy of continuous interstitial fluid glucose sensing that represents the crucial afferent arm of such a system. An important determinant of sensor accuracy is the physiological time lag of glucose transport from the vascular to the interstitial space. The purpose of current studies was to determine the physiological time lag of glucose transport from the vascular to the abdominal subcutaneous interstitial space in T1D. Method: Four microdialysis catheters were inserted into the abdominal subcutaneous space in 6 T1D subjects under overnight fasted conditions. Plasma glucose was maintained at 113.7 ± 6.3 mg/dl using a continuous intravenous insulin infusion. After sequential intravenous bolus administrations of glucose isotopes, timed plasma and interstitial fluid samples were collected chronologically and analyzed for tracer enrichments. Results: We observed a median (range) time lag of tracer appearance (time to detection) into the interstitial space after intravenous bolus of 6.8 (4.8-9.8) minutes, with all participants having detectable values by 9.8 minutes. Conclusions: We conclude that in the overnight fasted state in T1D adults, the delay of glucose appearance from the vascular to the interstitial space is less than 10 minutes, thereby implying that this minimal physiological time lag should not be a major impediment to the development of anBackground and Objective: The premise of effective closed-loop insulin therapy for type 1 diabetes (T1D) relies on the accuracy of continuous interstitial fluid glucose sensing that represents the crucial afferent arm of such a system. An important determinant of sensor accuracy is the physiological time lag of glucose transport from the vascular to the interstitial space. The purpose of current studies was to determine the physiological time lag of glucose transport from the vascular to the abdominal subcutaneous interstitial space in T1D. Method: Four microdialysis catheters were inserted into the abdominal subcutaneous space in 6 T1D subjects under overnight fasted conditions. Plasma glucose was maintained at 113.7 ± 6.3 mg/dl using a continuous intravenous insulin infusion. After sequential intravenous bolus administrations of glucose isotopes, timed plasma and interstitial fluid samples were collected chronologically and analyzed for tracer enrichments. Results: We observed a median (range) time lag of tracer appearance (time to detection) into the interstitial space after intravenous bolus of 6.8 (4.8-9.8) minutes, with all participants having detectable values by 9.8 minutes. Conclusions: We conclude that in the overnight fasted state in T1D adults, the delay of glucose appearance from the vascular to the interstitial space is less than 10 minutes, thereby implying that this minimal physiological time lag should not be a major impediment to the development of an effective closed-loop control system for T1D. … (more)
- Is Part Of:
- Journal of diabetes science and technology. Volume 9:Number 1(2015:Jan.)
- Journal:
- Journal of diabetes science and technology
- Issue:
- Volume 9:Number 1(2015:Jan.)
- Issue Display:
- Volume 9, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 9
- Issue:
- 1
- Issue Sort Value:
- 2015-0009-0001-0000
- Page Start:
- 63
- Page End:
- 68
- Publication Date:
- 2014-10-10
- Subjects:
- interstitial glucose concentration -- subcutaneous glucose transport -- type 1 diabetes -- microdialysis -- continuous glucose monitors
Diabetes -- Periodicals
Medical technology -- Periodicals
Diabetes Mellitus -- Periodicals
616.462005 - Journal URLs:
- http://ejournals.ebsco.com/direct.asp?JournalID=712321 ↗
http://www.jodsat.org/about.html ↗
http://online.sagepub.com/ ↗ - DOI:
- 10.1177/1932296814554797 ↗
- Languages:
- English
- ISSNs:
- 1932-2968
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6588.xml