Inclusion of the periodontal ligament in studies on the biomechanical behavior of fiber post-retained restorations: An in vitro study and three-dimensional finite element analysis. (March 2016)
- Record Type:
- Journal Article
- Title:
- Inclusion of the periodontal ligament in studies on the biomechanical behavior of fiber post-retained restorations: An in vitro study and three-dimensional finite element analysis. (March 2016)
- Main Title:
- Inclusion of the periodontal ligament in studies on the biomechanical behavior of fiber post-retained restorations: An in vitro study and three-dimensional finite element analysis
- Authors:
- González-Lluch, Carmen
Rodríguez-Cervantes, Pablo-Jesús
Forner, Leopoldo
Barjau, Amaya - Abstract:
- Endodontically treated teeth are known to have reduced structural strength. Periodontal ligament may influence fracture resistance. The purpose of this study was to assess the influence of including the periodontal ligament in biomechanical studies about endodontically treated and restored teeth. Forty human maxillary central incisors were treated endodontically and randomly divided into four groups: non-crowned (with and without an artificial ligament) and crowned (with and without an artificial ligament) with glass-ceramic crowns. All groups received prefabricated glass-fiber posts and a composite resin core. Specimens were tested, under a flexural–compressive load, until failure occurred. The failure mode was registered for all specimens. The failure loads were recorded and analyzed using an analysis of variance test ( p < 0.05). These results were compared with those predicted by a finite element model. The analysis of variance did not show significant differences between the use of crown on the failure load ( p = 0.331) and the use of periodontal ligament ( p = 0.185). A cohesive mode in crown appeared in crowned teeth and in core in non-crowned groups. For non-crowned teeth, adhesive failure occurred along the cement–enamel junction with a slight tendency in specimens without periodontal ligament. Furthermore, an unfavorable failure mode affects partially the root with no differences regarding non-crown specimens. In crowned teeth, the tendency was an adhesiveEndodontically treated teeth are known to have reduced structural strength. Periodontal ligament may influence fracture resistance. The purpose of this study was to assess the influence of including the periodontal ligament in biomechanical studies about endodontically treated and restored teeth. Forty human maxillary central incisors were treated endodontically and randomly divided into four groups: non-crowned (with and without an artificial ligament) and crowned (with and without an artificial ligament) with glass-ceramic crowns. All groups received prefabricated glass-fiber posts and a composite resin core. Specimens were tested, under a flexural–compressive load, until failure occurred. The failure mode was registered for all specimens. The failure loads were recorded and analyzed using an analysis of variance test ( p < 0.05). These results were compared with those predicted by a finite element model. The analysis of variance did not show significant differences between the use of crown on the failure load ( p = 0.331) and the use of periodontal ligament ( p = 0.185). A cohesive mode in crown appeared in crowned teeth and in core in non-crowned groups. For non-crowned teeth, adhesive failure occurred along the cement–enamel junction with a slight tendency in specimens without periodontal ligament. Furthermore, an unfavorable failure mode affects partially the root with no differences regarding non-crown specimens. In crowned teeth, the tendency was an adhesive failure along the cement–enamel junction. The model predicted a distribution of the safety factor consistent with these results. This study showed that inclusion of periodontal ligament is not particularly important on biomechanical behavior of post-retained restorations. However, we recommend its inclusion in fatigue studies. … (more)
- Is Part Of:
- Proceedings of the Institution of Mechanical Engineers. Volume 230:Number 3(2016:Mar.)
- Journal:
- Proceedings of the Institution of Mechanical Engineers
- Issue:
- Volume 230:Number 3(2016:Mar.)
- Issue Display:
- Volume 230, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 230
- Issue:
- 3
- Issue Sort Value:
- 2016-0230-0003-0000
- Page Start:
- 230
- Page End:
- 238
- Publication Date:
- 2016-03
- Subjects:
- Biomechanics -- fiber posts -- finite element model -- oral rehabilitation -- periodontal ligament -- restorative dentistry
Biomedical engineering -- Periodicals
Medical instruments and apparatus -- Periodicals
610.28 - Journal URLs:
- http://pih.sagepub.com/ ↗
http://journals.pepublishing.com/content/119779 ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/0954411916630006 ↗
- Languages:
- English
- ISSNs:
- 0954-4119
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6564.xml