Accuracy and Injection Force of the Gla-300 Injection Device Compared With Other Commercialized Disposable Insulin Pens. (January 2016)
- Record Type:
- Journal Article
- Title:
- Accuracy and Injection Force of the Gla-300 Injection Device Compared With Other Commercialized Disposable Insulin Pens. (January 2016)
- Main Title:
- Accuracy and Injection Force of the Gla-300 Injection Device Compared With Other Commercialized Disposable Insulin Pens
- Authors:
- Klonoff, David
Nayberg, Irina
Thonius, Marissa
See, Florian
Abdel-Tawab, Mona
Erbstein, Frank
Haak, Thomas - Abstract:
- Background: To deliver insulin glargine 300 U/mL (Gla-300), the widely used SoloSTAR ® pen has been modified to allow for accurate and precise delivery of required insulin units in one-third of the volume compared with insulin glargine 100 U/mL, while improving usability. Here we compare the accuracy and injection force of 3 disposable insulin pens: Gla-300 SoloSTAR ®, FlexPen ®, and KwikPen™. Methods: For the accuracy assessment, 60 of each of the 3 tested devices were used for the delivery of 3 different doses (1 U, half-maximal dose, and maximal dose), which were measured gravimetrically. For the injection force assessment, 20 pens of each of the 3 types were tested twice at half-maximal and once at maximal dose, at an injection speed of 6 U/s. Results: All tested pens met the International Organization for Standardization (ISO) requirements for dosing accuracy, with Gla-300 SoloSTAR showing the lowest between-dose variation (greatest reproducibility) at all dose levels. Mean injection force was significantly lower for Gla-300 SoloSTAR than for the other 2 pens at both half maximal and maximal doses ( P < .0271). Conclusion: All tested pens were accurate according to ISO criteria, and the Gla-300 SoloSTAR pen displayed the greatest reproducibility and lowest injection force of any of the 3 tested devices.
- Is Part Of:
- Journal of diabetes science and technology. Volume 10:Number 1(2016:Jan.)
- Journal:
- Journal of diabetes science and technology
- Issue:
- Volume 10:Number 1(2016:Jan.)
- Issue Display:
- Volume 10, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 10
- Issue:
- 1
- Issue Sort Value:
- 2016-0010-0001-0000
- Page Start:
- 125
- Page End:
- 130
- Publication Date:
- 2016-01
- Subjects:
- accuracy -- Gla-300 SoloSTAR -- injection force -- insulin pen
Diabetes -- Periodicals
Medical technology -- Periodicals
Diabetes Mellitus -- Periodicals
616.462005 - Journal URLs:
- http://ejournals.ebsco.com/direct.asp?JournalID=712321 ↗
http://www.jodsat.org/about.html ↗
http://online.sagepub.com/ ↗ - DOI:
- 10.1177/1932296815601441 ↗
- Languages:
- English
- ISSNs:
- 1932-2968
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6551.xml