Statistical Monitoring in Clinical Trials: Best Practices for Detecting Data Anomalies Suggestive of Fabrication or Misconduct. (March 2016)
- Record Type:
- Journal Article
- Title:
- Statistical Monitoring in Clinical Trials: Best Practices for Detecting Data Anomalies Suggestive of Fabrication or Misconduct. (March 2016)
- Main Title:
- Statistical Monitoring in Clinical Trials
- Authors:
- Knepper, David
Lindblad, Anne S.
Sharma, Gaurav
Gensler, Gary R.
Manukyan, Zorayr
Matthews, Abigail G.
Seifu, Yodit - Abstract:
- Background: Traditional site-monitoring techniques are not optimal in finding data fabrication and other nonrandom data distributions with the greatest potential for jeopardizing the validity of study results. TransCelerate BioPharma conducted an experiment testing the utility of statistical methods for detecting implanted fabricated data and other signals of noncompliance. Methods: TransCelerate tested statistical monitoring on a data set from a chronic obstructive pulmonary disease (COPD) clinical study with 178 sites and 1554 subjects. Fabricated data were selectively implanted in 7 sites and 43 subjects by expert clinicians in COPD. The data set was partitioned to simulate studies of different sizes. Analyses of vital signs, spirometry, visit dates, and adverse events included distributions of standard deviations, correlations, repeated values, digit preference, and outlier/inlier detection. An interpretation team, including clinicians, statisticians, site monitoring, and data management, reviewed the results and created an algorithm to flag sites for fabricated data. Results: The algorithm identified 11 sites (19%), 19 sites (31%), 28 sites (16%), and 45 sites (25%) as having potentially fabricated data for studies 2A, 2, 1A, and 1, respectively. For study 2A, 3 of 7 sites with fabricated data were detected, 5 of 7 were detected for studies 2 and 1A, and 6 of 7 for study 1. Except for study 2A, the algorithm had good sensitivity and specificity (>70%) for identifyingBackground: Traditional site-monitoring techniques are not optimal in finding data fabrication and other nonrandom data distributions with the greatest potential for jeopardizing the validity of study results. TransCelerate BioPharma conducted an experiment testing the utility of statistical methods for detecting implanted fabricated data and other signals of noncompliance. Methods: TransCelerate tested statistical monitoring on a data set from a chronic obstructive pulmonary disease (COPD) clinical study with 178 sites and 1554 subjects. Fabricated data were selectively implanted in 7 sites and 43 subjects by expert clinicians in COPD. The data set was partitioned to simulate studies of different sizes. Analyses of vital signs, spirometry, visit dates, and adverse events included distributions of standard deviations, correlations, repeated values, digit preference, and outlier/inlier detection. An interpretation team, including clinicians, statisticians, site monitoring, and data management, reviewed the results and created an algorithm to flag sites for fabricated data. Results: The algorithm identified 11 sites (19%), 19 sites (31%), 28 sites (16%), and 45 sites (25%) as having potentially fabricated data for studies 2A, 2, 1A, and 1, respectively. For study 2A, 3 of 7 sites with fabricated data were detected, 5 of 7 were detected for studies 2 and 1A, and 6 of 7 for study 1. Except for study 2A, the algorithm had good sensitivity and specificity (>70%) for identifying sites with fabricated data. Conclusions: We recommend a cross-functional, collaborative approach to statistical monitoring that can adapt to study design and data source and use a combination of statistical screening techniques and confirmatory graphics. … (more)
- Is Part Of:
- Therapeutic innovation & regulatory science. Volume 50:Number 2(2016:Mar.)
- Journal:
- Therapeutic innovation & regulatory science
- Issue:
- Volume 50:Number 2(2016:Mar.)
- Issue Display:
- Volume 50, Issue 2 (2016)
- Year:
- 2016
- Volume:
- 50
- Issue:
- 2
- Issue Sort Value:
- 2016-0050-0002-0000
- Page Start:
- 144
- Page End:
- 154
- Publication Date:
- 2016-03
- Subjects:
- statistical monitoring -- central monitoring -- risk-based monitoring -- fabrication -- fraud -- misconduct -- TransCelerate
Drugs -- Periodicals
Pharmacology -- Periodicals
Drugs -- Research -- Periodicals
Drugs -- Testing -- Periodicals
615.1 - Journal URLs:
- http://dij.sagepub.com/ ↗
http://dij.sagepub.com/content/by/year ↗
http://journals.sagepub.com/toc/DIJ/current ↗
https://www.springer.com/journal/43441 ↗
http://www.sagepublications.com/ ↗ - DOI:
- 10.1177/2168479016630576 ↗
- Languages:
- English
- ISSNs:
- 2168-4790
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6557.xml