Liquid Sampling–Atmospheric Pressure Glow Discharge as a Secondary Excitation Source for Laser Ablation-Generated Aerosols: Parametric Dependence and Robustness to Particle Loading. Issue 1 (January 2015)
- Record Type:
- Journal Article
- Title:
- Liquid Sampling–Atmospheric Pressure Glow Discharge as a Secondary Excitation Source for Laser Ablation-Generated Aerosols: Parametric Dependence and Robustness to Particle Loading. Issue 1 (January 2015)
- Main Title:
- Liquid Sampling–Atmospheric Pressure Glow Discharge as a Secondary Excitation Source for Laser Ablation-Generated Aerosols: Parametric Dependence and Robustness to Particle Loading
- Authors:
- Manard, Benjamin T.
Konegger-Kappel, Stefanie
Gonzalez, Jhanis J.
Chirinos, Jose
Dong, Meirong
Mao, Xianglei
Marcus, R. Kenneth
Russo, Richard E. - Abstract:
- Liquid sampling–atmospheric pressure glow discharge (LS-APGD) microplasma is being developed as a secondary vaporization–excitation source for the optical emission analysis of laser ablation (LA)-generated particle populations. The practicalities of this coupling are evaluated by determining the influence of source parameters on the emission response and the plasma's robustness upon LA introduction of easily ionized elements (EIEs). The influence of discharge current (45–70 mA), LA carrier gas flow rate (0.1–0.8 L min –1 ), and electrode separation distance (0.5–3.5 mm) was studied by measuring Cu emission lines after ablation of a brass sample. Best emission responses were observed for high-discharge currents, low He carrier gas flow rates, and relatively small (<1.5 mm) electrode gaps. Plasma robustness and spectroscopic matrix effects were studied by monitoring Mg(II): Mg(I) intensity ratios and N2 -derived plasma rotational temperatures after the ablation of Sr- and Ca-containing pellets. Plasma robustness investigations showed that the plasma is not appreciably affected by the particle loadings, with the microplasma being slightly more ionizing in the case of Ca introduction. In neither case did the concentration of the concomitant element change the robustness values, implying a high level of robustness. Introduction of the LA particles results in slight increases in the rotational temperatures (~10% relative), with Ca-containing particles having a greater effect thanLiquid sampling–atmospheric pressure glow discharge (LS-APGD) microplasma is being developed as a secondary vaporization–excitation source for the optical emission analysis of laser ablation (LA)-generated particle populations. The practicalities of this coupling are evaluated by determining the influence of source parameters on the emission response and the plasma's robustness upon LA introduction of easily ionized elements (EIEs). The influence of discharge current (45–70 mA), LA carrier gas flow rate (0.1–0.8 L min –1 ), and electrode separation distance (0.5–3.5 mm) was studied by measuring Cu emission lines after ablation of a brass sample. Best emission responses were observed for high-discharge currents, low He carrier gas flow rates, and relatively small (<1.5 mm) electrode gaps. Plasma robustness and spectroscopic matrix effects were studied by monitoring Mg(II): Mg(I) intensity ratios and N2 -derived plasma rotational temperatures after the ablation of Sr- and Ca-containing pellets. Plasma robustness investigations showed that the plasma is not appreciably affected by the particle loadings, with the microplasma being slightly more ionizing in the case of Ca introduction. In neither case did the concentration of the concomitant element change the robustness values, implying a high level of robustness. Introduction of the LA particles results in slight increases in the rotational temperatures (~10% relative), with Ca-containing particles having a greater effect than Sr-containing particles. The observed variation of 9% in the plasma rotational temperature is in the same order of magnitude as the short-term reproducibility determined by the proposed LA-LS-APGD system. The determined rotational temperatures ranged from 1047 to 1212 K upon introducing various amounts of Ca and Sr. The relative immunity to LA particle-induced matrix effects is attributed to the relatively long residence times and high power densities (10 W mm –3 ) of the LS-APGD microplasma. … (more)
- Is Part Of:
- Applied spectroscopy. Volume 69:Issue 1(2015)
- Journal:
- Applied spectroscopy
- Issue:
- Volume 69:Issue 1(2015)
- Issue Display:
- Volume 69, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 69
- Issue:
- 1
- Issue Sort Value:
- 2015-0069-0001-0000
- Page Start:
- 58
- Page End:
- 66
- Publication Date:
- 2015-01
- Subjects:
- Liquid sampling–atmospheric pressure glow discharge; -- LS-APGD; -- Laser ablation; -- Optical emission spectroscopy; -- Excitation conditions; -- Robustness; -- Particle loading.
Spectrum analysis -- Periodicals
543.505 - Journal URLs:
- http://asp.sagepub.com/ ↗
http://www.ingentaconnect.com/content/sas/sas ↗
http://www.uk.sagepub.com/home.nav ↗
http://firstsearch.oclc.org/journal=0003-7028;screen=info;ECOIP ↗ - DOI:
- 10.1366/14-07585 ↗
- Languages:
- English
- ISSNs:
- 0003-7028
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6552.xml