Influence of different reconstruction parameters in the visualization of intracranial stents using C-arm flat panel CT angiography: experience in an animal model. (February 2016)
- Record Type:
- Journal Article
- Title:
- Influence of different reconstruction parameters in the visualization of intracranial stents using C-arm flat panel CT angiography: experience in an animal model. (February 2016)
- Main Title:
- Influence of different reconstruction parameters in the visualization of intracranial stents using C-arm flat panel CT angiography: experience in an animal model
- Authors:
- Ott, Sabine
Struffert, Tobias
Saake, Marc
Gölitz, Philipp
Adamek, Edyta
Doerfler, Arnd - Abstract:
- Background: C-arm flat panel computed tomography angiography (CA-CTA) is a relatively new imaging modality. Consequently, knowledge about postprocessing parameters and their influence on image quality is still limited, especially for the visualization of implanted microstents. Purpose: To optimize reconstruction parameters by evaluating the influence of these different parameters for CA-CTA visualization of microstents in an animal model. Material and Methods: Eleven microstents were implanted within the left common carotid artery of 11 New Zealand white rabbits. Both CA-CTA, using intra-venous delivery of contrast material, and conventional digital subtraction angiography (DSA) was performed. CA-CTA datasets were reconstructed using three different image characteristics (normal, sharp, smooth). Two experienced neuroradiologists evaluated the image quality and performed measurements of inner and outer stent diameters as well as measurements of the lumen area. Results: Stent deployment was performed successfully in all animals. Inter-observer correlation coefficient for all measurements was high (r = 0.87–0.92). Lumen area and inner stent diameter were significantly smaller in image characteristic "smooth" ( P < 0.01) than in "sharp" and "normal". Outer stent diameter was larger in "smooth" than in "sharp" and "normal" ( P < 0.01). Stent strut size was significantly wider using image characteristic "smooth". "Sharp" and "normal" compared best to DSA, with "sharp" providingBackground: C-arm flat panel computed tomography angiography (CA-CTA) is a relatively new imaging modality. Consequently, knowledge about postprocessing parameters and their influence on image quality is still limited, especially for the visualization of implanted microstents. Purpose: To optimize reconstruction parameters by evaluating the influence of these different parameters for CA-CTA visualization of microstents in an animal model. Material and Methods: Eleven microstents were implanted within the left common carotid artery of 11 New Zealand white rabbits. Both CA-CTA, using intra-venous delivery of contrast material, and conventional digital subtraction angiography (DSA) was performed. CA-CTA datasets were reconstructed using three different image characteristics (normal, sharp, smooth). Two experienced neuroradiologists evaluated the image quality and performed measurements of inner and outer stent diameters as well as measurements of the lumen area. Results: Stent deployment was performed successfully in all animals. Inter-observer correlation coefficient for all measurements was high (r = 0.87–0.92). Lumen area and inner stent diameter were significantly smaller in image characteristic "smooth" ( P < 0.01) than in "sharp" and "normal". Outer stent diameter was larger in "smooth" than in "sharp" and "normal" ( P < 0.01). Stent strut size was significantly wider using image characteristic "smooth". "Sharp" and "normal" compared best to DSA, with "sharp" providing the closest match to DSA measurements, with the trade-off of significantly more noise than in the "normal" reconstructions. Conclusion: The use of different image characteristics in the postprocessing of CA-CTA datasets has an influence on the visualization of implanted stents. Image characteristic "sharp" and "normal" compared best to DSA. … (more)
- Is Part Of:
- Acta radiologica. Volume 57:Number 2(2016:Feb.)
- Journal:
- Acta radiologica
- Issue:
- Volume 57:Number 2(2016:Feb.)
- Issue Display:
- Volume 57, Issue 2 (2016)
- Year:
- 2016
- Volume:
- 57
- Issue:
- 2
- Issue Sort Value:
- 2016-0057-0002-0000
- Page Start:
- 233
- Page End:
- 240
- Publication Date:
- 2016-02
- Subjects:
- Digital subtraction angiography -- C-arm flat panel computed tomography angiography -- stent visualization -- intracranial stent -- animal model
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1177/0284185115571988 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6542.xml