Radiofrequency ablation of the great saphenous vein, comparing one versus two treatment cycles for the proximal vein segment. (December 2015)
- Record Type:
- Journal Article
- Title:
- Radiofrequency ablation of the great saphenous vein, comparing one versus two treatment cycles for the proximal vein segment. (December 2015)
- Main Title:
- Radiofrequency ablation of the great saphenous vein, comparing one versus two treatment cycles for the proximal vein segment
- Authors:
- Sufian, S
Arnez, A
Labropoulos, N
Nguyen, K
Satwah, V
Marquez, J
Chowla, A
Lakhanpal, S - Abstract:
- Objective: To evaluate the results of radiofrequency ablation (RFA) of the great saphenous vein (GSV) using one versus two 20 s energy cycle treatment in the proximal 7 cm segment of the GSV. Methods: All patients who underwent RFA of the GSV from 1 May 2013 to 30 September 2013 in eight of our vein centers were included. Duplex ultrasound scans (DUSs) were performed prior to treatment on all patients and 2–3 days, and 1 month after procedure. Demographic data, GSV diameters, and other relevant data were recorded. Clinical, Etiologic, Anatomic, Pathologic (CEAP) classification and Venous Clinical Severity Scores (VCSSs) were determined prior to ablation and one month later. Patients who developed endovenous heat induced thrombosis (EHIT) were followed till resolution. Results: A total of 205 patients had one cycle treatment (group A) and 204 had two cycle treatment (group B). The two groups were comparable in their demography, CEAP classification, and VCSS scores. The rate of failure of ablation and incidence of EHIT were also not significantly different. The incidence of complications was low, <5% in both groups and all were minor. Conclusion: Two cycle treatment of the proximal GSV for vein ablation does not improve the success rate of vein closure in the short term, compared to one cycle treatment. It also does not increase the risks of DVT, EHIT, major bleeding, and other complications. However, we do not know at what diameter two cycles may be superior to one cycle.
- Is Part Of:
- Phlebology. Volume 30:Number 10(2015)
- Journal:
- Phlebology
- Issue:
- Volume 30:Number 10(2015)
- Issue Display:
- Volume 30, Issue 10 (2015)
- Year:
- 2015
- Volume:
- 30
- Issue:
- 10
- Issue Sort Value:
- 2015-0030-0010-0000
- Page Start:
- 724
- Page End:
- 728
- Publication Date:
- 2015-12
- Subjects:
- Great saphenous vein ablation -- radiofrequency ablation -- Venous Severity Score
Veins -- Diseases -- Periodicals
616.14 - Journal URLs:
- http://phl.sagepub.com/ ↗
http://www.uk.sagepub.com/home.nav ↗
http://link.springer-ny.com/ ↗
http://phleb.rsmjournals.com/ ↗ - DOI:
- 10.1177/0268355514556142 ↗
- Languages:
- English
- ISSNs:
- 0268-3555
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6539.xml