An automated LS(β)- NaI(Tl)(γ) coincidence system as absolute standard for radioactivity measurements. (July 2018)
- Record Type:
- Journal Article
- Title:
- An automated LS(β)- NaI(Tl)(γ) coincidence system as absolute standard for radioactivity measurements. (July 2018)
- Main Title:
- An automated LS(β)- NaI(Tl)(γ) coincidence system as absolute standard for radioactivity measurements
- Authors:
- Joseph, Leena
Das, A.P.
Ravindra, Anuradha
Kulkarni, D.B.
Kulkarni, M.S. - Abstract:
- Abstract: 4πβ-γ coincidence method is a powerful and widely used method to determine the absolute activity concentration of radioactive solutions. A new automated liquid scintillator based coincidence system has been designed, developed, tested and established as absolute standard for radioactivity measurements. The automation is achieved using PLC (programmable logic controller) and SCADA (supervisory control and data acquisition). Radioactive solution of 60 Co was standardized to compare the performance of the automated system with proportional counter based absolute standard maintained in the laboratory. The activity concentrations determined using these two systems were in very good agreement; the new automated system can be used for absolute measurement of activity concentration of radioactive solutions. Highlights: A new automated liquid scintillator based coincidence system has been designed, developed, tested. The automation is achieved using PLC (programmable logic controller) and SCADA (supervisory control and data acquisition). Radioactive solution of 60 Co was standardized to compare performance with proportional counter based primary standard. The results of activity concentration obtained using two systems are comparable within uncertainty limits.
- Is Part Of:
- Applied radiation and isotopes. Volume 137(2018:Jul.)
- Journal:
- Applied radiation and isotopes
- Issue:
- Volume 137(2018:Jul.)
- Issue Display:
- Volume 137 (2018)
- Year:
- 2018
- Volume:
- 137
- Issue Sort Value:
- 2018-0137-0000-0000
- Page Start:
- 28
- Page End:
- 32
- Publication Date:
- 2018-07
- Subjects:
- Liquid scintillator -- Proportional counter -- Coincidence -- Standardisation
Radiology -- Periodicals
Radiation -- Industrial applications -- Periodicals
Nuclear chemistry -- Periodicals
Internet resource
Periodical
660.298 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09698043 ↗
http://catalog.hathitrust.org/api/volumes/oclc/27456684.html ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.apradiso.2018.02.030 ↗
- Languages:
- English
- ISSNs:
- 0969-8043
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1576.565000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6522.xml