Full-field in vitro measurements and in silico predictions of strain shielding in the implanted femur after total hip arthroplasty. (August 2015)
- Record Type:
- Journal Article
- Title:
- Full-field in vitro measurements and in silico predictions of strain shielding in the implanted femur after total hip arthroplasty. (August 2015)
- Main Title:
- Full-field in vitro measurements and in silico predictions of strain shielding in the implanted femur after total hip arthroplasty
- Authors:
- Chanda, Souptick
Dickinson, Alexander
Gupta, Sanjay
Browne, Martin - Abstract:
- Alterations in bone strain as a result of implantation may contribute towards periprosthetic bone density changes after total hip arthroplasty. Computational models provide full-field strain predictions in implant–bone constructs; however, these predictions should be verified using experimental models wherever it is possible. In this work, finite element predictions of surface strains in intact and implanted composite femurs were verified using digital image correlation. Relationships were sought between post-implantation strain states across seven defined Gruen zones and clinically observed longer-term bone density changes. Computational predictions of strain distributions in intact and implanted femurs were compared to digital image correlation measurements in two regions of interest. Regression analyses indicated a strong linear correlation between measurements and predictions (R = 0.927 intact, 0.926 implanted) with low standard error (standard error = 38 µε intact, 26 µε implanted). Pre- to post-operative changes in measured and predicted surface strains were found to relate qualitatively to clinically observed volumetric bone density changes across seven Gruen zones: marked proximal bone density loss corresponded with a 50%−64% drop in surface strain, and slight distal density changes corresponded with 4%−14% strain increase. These results support the use of digital image correlation as a pre-clinical tool for predicting post-implantation strain shielding, indicativeAlterations in bone strain as a result of implantation may contribute towards periprosthetic bone density changes after total hip arthroplasty. Computational models provide full-field strain predictions in implant–bone constructs; however, these predictions should be verified using experimental models wherever it is possible. In this work, finite element predictions of surface strains in intact and implanted composite femurs were verified using digital image correlation. Relationships were sought between post-implantation strain states across seven defined Gruen zones and clinically observed longer-term bone density changes. Computational predictions of strain distributions in intact and implanted femurs were compared to digital image correlation measurements in two regions of interest. Regression analyses indicated a strong linear correlation between measurements and predictions (R = 0.927 intact, 0.926 implanted) with low standard error (standard error = 38 µε intact, 26 µε implanted). Pre- to post-operative changes in measured and predicted surface strains were found to relate qualitatively to clinically observed volumetric bone density changes across seven Gruen zones: marked proximal bone density loss corresponded with a 50%−64% drop in surface strain, and slight distal density changes corresponded with 4%−14% strain increase. These results support the use of digital image correlation as a pre-clinical tool for predicting post-implantation strain shielding, indicative of long-term bone adaptations. … (more)
- Is Part Of:
- Proceedings of the Institution of Mechanical Engineers. Volume 229:Number 8(2015:Aug.)
- Journal:
- Proceedings of the Institution of Mechanical Engineers
- Issue:
- Volume 229:Number 8(2015:Aug.)
- Issue Display:
- Volume 229, Issue 8 (2015)
- Year:
- 2015
- Volume:
- 229
- Issue:
- 8
- Issue Sort Value:
- 2015-0229-0008-0000
- Page Start:
- 549
- Page End:
- 559
- Publication Date:
- 2015-08
- Subjects:
- Total hip arthroplasty -- bone adaptation -- mechanical testing -- digital image correlation -- finite element analysis
Biomedical engineering -- Periodicals
Medical instruments and apparatus -- Periodicals
610.28 - Journal URLs:
- http://pih.sagepub.com/ ↗
http://journals.pepublishing.com/content/119779 ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/0954411915591617 ↗
- Languages:
- English
- ISSNs:
- 0954-4119
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6525.xml