Coronary artery rotation in native and stented porcine coronary arteries. Issue 6 (24th August 2017)
- Record Type:
- Journal Article
- Title:
- Coronary artery rotation in native and stented porcine coronary arteries. Issue 6 (24th August 2017)
- Main Title:
- Coronary artery rotation in native and stented porcine coronary arteries
- Authors:
- Challa, Karthik K.
Kansal, Mayank M.
Frazin, Leon
Nikanorov, Alex
Kohler, Robert
Martinsen, Brad J.
Vidovich, Mladen I. - Abstract:
- Abstract: Introduction: Coronary arteries are exposed to several complex biomechanical forces during the cardiac cycle. These biomechanical forces potentially contribute to both native coronary artery disease, development of atherosclerosis and eventual stent failure. The aim of the present study was to characterize and define coronary artery axial rotation and the effect of stent implantation on this biomechanical factor. Methods: Intravascular ultrasound (IVUS) images were obtained from porcine coronary arteries and analyzed in ultrasound analysis software used to evaluate myocardial strain and torsion in echocardiography. In this study the software was utilized for a novel application to evaluate coronary artery rotation and time‐to‐peak (TTP) rotation in porcine coronary arteries. Clockwise (CW) and counterclockwise (CCW) rotation of coronary arteries during the cardiac cycle and (TTP) rotation were measured. Results: A total of 11 (4 LAD, 4 LCX, 3 RCA) coronary artery segments were independently analyzed pre‐ and post‐stent implantation for a total of 22 IVUS runs. CW and CCW rotation and TTP varied widely within coronary artery segments and between different coronary arteries. Stent implantation impacted degree, direction and TTP of coronary rotation. Measurement reliability was assessed and the intraclass correlation coefficient for maximum average CCW was 0.990 (95% confidence interval 0.980–0.996, P < 0.0001), indicating excellent agreement. Conclusions: CoronaryAbstract: Introduction: Coronary arteries are exposed to several complex biomechanical forces during the cardiac cycle. These biomechanical forces potentially contribute to both native coronary artery disease, development of atherosclerosis and eventual stent failure. The aim of the present study was to characterize and define coronary artery axial rotation and the effect of stent implantation on this biomechanical factor. Methods: Intravascular ultrasound (IVUS) images were obtained from porcine coronary arteries and analyzed in ultrasound analysis software used to evaluate myocardial strain and torsion in echocardiography. In this study the software was utilized for a novel application to evaluate coronary artery rotation and time‐to‐peak (TTP) rotation in porcine coronary arteries. Clockwise (CW) and counterclockwise (CCW) rotation of coronary arteries during the cardiac cycle and (TTP) rotation were measured. Results: A total of 11 (4 LAD, 4 LCX, 3 RCA) coronary artery segments were independently analyzed pre‐ and post‐stent implantation for a total of 22 IVUS runs. CW and CCW rotation and TTP varied widely within coronary artery segments and between different coronary arteries. Stent implantation impacted degree, direction and TTP of coronary rotation. Measurement reliability was assessed and the intraclass correlation coefficient for maximum average CCW was 0.990 (95% confidence interval 0.980–0.996, P < 0.0001), indicating excellent agreement. Conclusions: Coronary arteries display wide spectrum of CW and CCW rotation during the cardiac cycle. Coronary stents impact the degree and direction of coronary artery rotation. The implications of these findings on development of atherosclerosis and stent failure require further investigation. … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 91:Issue 6(2018)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 91:Issue 6(2018)
- Issue Display:
- Volume 91, Issue 6 (2018)
- Year:
- 2018
- Volume:
- 91
- Issue:
- 6
- Issue Sort Value:
- 2018-0091-0006-0000
- Page Start:
- 1092
- Page End:
- 1100
- Publication Date:
- 2017-08-24
- Subjects:
- coronary -- IVUS -- porcine -- rotation
Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.27247 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 6502.xml