A Microscopic and Biomarker Evaluation of Embolic Filter Debris Collected During Carotid Artery Stenting. (April 2016)
- Record Type:
- Journal Article
- Title:
- A Microscopic and Biomarker Evaluation of Embolic Filter Debris Collected During Carotid Artery Stenting. (April 2016)
- Main Title:
- A Microscopic and Biomarker Evaluation of Embolic Filter Debris Collected During Carotid Artery Stenting
- Authors:
- Yang, Mark
Yu, Yan
Walsh, William R.
Yang, Jia-Lin
Baker, Luke
Lennox, Andrew F.
Crowe, Philip J.
Varcoe, Ramon L. - Abstract:
- Purpose: To evaluate and characterize debris retrieved from the cerebral embolic protection devices (EPDs) used during carotid artery stenting (CAS) and compare debris size, volume, tissue types, cellular composition, and protein biomarker expression in symptomatic and asymptomatic patients.Methods: Distal protection filters were retrieved from 22 consecutive patients (mean age 71.6 years, range 52–85; 16 men) undergoing elective CAS between July 2012 and February 2014 for >70% internal carotid artery stenosis (mean 85.4%±10.3%). Six patients were symptomatic. The debris within each EPD was visually characterized using stereomicroscopy and then processed for histology and immunohistochemistry. Biomarkers were immunohistochemically measured to evaluate plaque stability [matrix metalloproteinase-9 (MMP-9)], inflammation [glycoprotein CD68 and interleukin-6 (IL-6)], or phenotype [smooth muscle (SM)-actin and type IV collagen]. The immunohistochemical results were measured using semiquantitative grading criteria based on both staining intensity and distribution in the samples.Results: Macroscopic debris was visible in 5/22 EPDs; 3 of the 5 filters came from symptomatic patients. Microscopic debris was detected in all filters and ranged in size from 0.01 to 8.57 mm 2 . Debris consisted of calcified, fibrous, and necrotic tissue, as well as fibrin and foam cells with no significant difference between the symptomatic and asymptomatic groups. There was no association between thePurpose: To evaluate and characterize debris retrieved from the cerebral embolic protection devices (EPDs) used during carotid artery stenting (CAS) and compare debris size, volume, tissue types, cellular composition, and protein biomarker expression in symptomatic and asymptomatic patients.Methods: Distal protection filters were retrieved from 22 consecutive patients (mean age 71.6 years, range 52–85; 16 men) undergoing elective CAS between July 2012 and February 2014 for >70% internal carotid artery stenosis (mean 85.4%±10.3%). Six patients were symptomatic. The debris within each EPD was visually characterized using stereomicroscopy and then processed for histology and immunohistochemistry. Biomarkers were immunohistochemically measured to evaluate plaque stability [matrix metalloproteinase-9 (MMP-9)], inflammation [glycoprotein CD68 and interleukin-6 (IL-6)], or phenotype [smooth muscle (SM)-actin and type IV collagen]. The immunohistochemical results were measured using semiquantitative grading criteria based on both staining intensity and distribution in the samples.Results: Macroscopic debris was visible in 5/22 EPDs; 3 of the 5 filters came from symptomatic patients. Microscopic debris was detected in all filters and ranged in size from 0.01 to 8.57 mm 2 . Debris consisted of calcified, fibrous, and necrotic tissue, as well as fibrin and foam cells with no significant difference between the symptomatic and asymptomatic groups. There was no association between the degree or type of embolic material and stenosis severity, carotid tortuosity, calcium grade, soft plaque, or arch type. Symptomatic patients had a larger volume of debris (8.24 vs 0.58 mm 3, p<0.01), mean particle size (1.30 vs 0.32 mm 2, p<0.001), and expression of biomarkers IL-6 (2.17 vs 0.81, p<0.05), CD68 (2.00 vs 0.38, p<0.01), SM-actin (1.00 vs 0.25, p=0.055), type IV collagen (1.17 vs 0.25, p=0.082), and MMP-9 (1.00 vs 0.06, p<0.05).Conclusion: Histological analysis revealed particulate embolization in all EPDs used during CAS. Symptomatic patients had a larger volume of embolic debris, mean particle size, and the biomarkers associated with inflammation, necrotic core, and diminished fibrous cap. … (more)
- Is Part Of:
- Journal of endovascular therapy. Volume 23:Number 2(2016:Apr.)
- Journal:
- Journal of endovascular therapy
- Issue:
- Volume 23:Number 2(2016:Apr.)
- Issue Display:
- Volume 23, Issue 2 (2016)
- Year:
- 2016
- Volume:
- 23
- Issue:
- 2
- Issue Sort Value:
- 2016-0023-0002-0000
- Page Start:
- 275
- Page End:
- 284
- Publication Date:
- 2016-04
- Subjects:
- angioplasty -- atherosclerosis -- biomarkers -- carotid artery -- carotid artery stenting -- embolic protection device -- filter -- immunohistochemistry -- histology -- interleukin-6 -- matrix metalloproteinase-9 -- plaque -- smooth muscle actin -- stent
Blood-vessels -- Endoscopic surgery -- Periodicals
Angioscopy -- Periodicals
Intravenous catheterization -- Periodicals
Peripheral vascular diseases -- Treatment -- Periodicals
Vascular Surgical Procedures -- Periodicals
Angioscopy -- Periodicals
Catheterization, Peripheral -- Periodicals
Peripheral Vascular Diseases -- therapy -- Periodicals
Angioscopie
Maladies vasculaires périphériques
617.413 - Journal URLs:
- http://jet.sagepub.com/ ↗
http://www.jevt.org ↗
http://www.uk.sagepub.com ↗ - DOI:
- 10.1177/1526602816628284 ↗
- Languages:
- English
- ISSNs:
- 1526-6028
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6499.xml