A Structured Review Addressing the Use of Radiographic Measures of Alignment and the Definition of Acceptability in Patients with Distal Radius Fractures. (December 2015)
- Record Type:
- Journal Article
- Title:
- A Structured Review Addressing the Use of Radiographic Measures of Alignment and the Definition of Acceptability in Patients with Distal Radius Fractures. (December 2015)
- Main Title:
- A Structured Review Addressing the Use of Radiographic Measures of Alignment and the Definition of Acceptability in Patients with Distal Radius Fractures
- Authors:
- Lalone, Emily A.
Grewal, Ruby
King, Graham J. W.
MacDermid, Joy C. - Abstract:
- Background: Standard radiographs are routinely used in clinical care to characterize the severity of a distal radius fracture and to monitor patients following a distal radius fracture. The objective of this review was to describe the range and variability of radiographic measures described in the literature in patients following a distal radius fracture. Methods: A structured literature review was conducted using the Embase and PubMed databases. Inclusion criteria included full-text publications which employed radiographic measures to examine 100 or more participants following a distal radius fracture. A standardized data extraction form was used to identify study design, fracture classification systems, the types of and definitions of radiographic measurements, and acceptability criteria following distal radius fractures. Results: From an initial 263 studies, 31 studies were included in the final data extraction process. A narrative synthesis of the articles included in this review indicated that there was a set of commonly used radiographic measurements examined in patients with a distal radius fracture which included radial inclination, volar/dorsal tilt, intra-articular step/gap, and a measure of ulnar variance/radial shortening. While 52 % of studies referenced or published a standardized measurement technique, there was substantial variability in the actual description of each radiographic measurement performed. Conclusions: Substantial variability in how radiographicBackground: Standard radiographs are routinely used in clinical care to characterize the severity of a distal radius fracture and to monitor patients following a distal radius fracture. The objective of this review was to describe the range and variability of radiographic measures described in the literature in patients following a distal radius fracture. Methods: A structured literature review was conducted using the Embase and PubMed databases. Inclusion criteria included full-text publications which employed radiographic measures to examine 100 or more participants following a distal radius fracture. A standardized data extraction form was used to identify study design, fracture classification systems, the types of and definitions of radiographic measurements, and acceptability criteria following distal radius fractures. Results: From an initial 263 studies, 31 studies were included in the final data extraction process. A narrative synthesis of the articles included in this review indicated that there was a set of commonly used radiographic measurements examined in patients with a distal radius fracture which included radial inclination, volar/dorsal tilt, intra-articular step/gap, and a measure of ulnar variance/radial shortening. While 52 % of studies referenced or published a standardized measurement technique, there was substantial variability in the actual description of each radiographic measurement performed. Conclusions: Substantial variability in how radiographic measurements are defined in large clinical studies as seen in this review suggest a need for consensus on the assessment and interpretations of radiographic measures used in patients following a distal radius fracture. Guidelines for radiographic measures should be established to ensure consistency between research and treatment centers. … (more)
- Is Part Of:
- Hand. Volume 10:Number 3(2015)
- Journal:
- Hand
- Issue:
- Volume 10:Number 3(2015)
- Issue Display:
- Volume 10, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 10
- Issue:
- 4
- Issue Sort Value:
- 2015-0010-0004-0000
- Page Start:
- 621
- Page End:
- 638
- Publication Date:
- 2015-12
- Subjects:
- Structured review -- X-ray -- Radiographic -- Alignment -- Distal radius -- Fractures
Hand -- Surgery -- Periodicals
Hand -- Surgery
Periodicals
617.57005 - Journal URLs:
- http://www.springerlink.com/content/119980/ ↗
http://journals.sagepub.com/toc/HAN/current ↗
http://www.springer.com/gb/ ↗ - DOI:
- 10.1007/s11552-015-9772-9 ↗
- Languages:
- English
- ISSNs:
- 1558-9447
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4241.550050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6501.xml