Measurement of the Radiographic Anatomy of the Small and Ring Metacarpals using Computerized Tomographic Scans. (December 2015)
- Record Type:
- Journal Article
- Title:
- Measurement of the Radiographic Anatomy of the Small and Ring Metacarpals using Computerized Tomographic Scans. (December 2015)
- Main Title:
- Measurement of the Radiographic Anatomy of the Small and Ring Metacarpals using Computerized Tomographic Scans
- Authors:
- Rivlin, Michael
Kim, Nayoung
Lutsky, Kevin F.
Beredjiklian, Pedro K. - Abstract:
- Background: To date, only plain radiographic definitions of normal anatomical parameters have been described. Our study aims to describe normal anatomic measurements of small and ring metacarpals using a novel digital reconstruction technique based on raw CT image data. We hypothesize that current plain radiographic data incorrectly describes normal metacarpal anatomy in the lateral plane. Methods: Thirty-five scans of the small and 30 scans of the ring metacarpals form the basis for this study. Using a custom digital 3D image reformatting software, CT sections were reconstructed in the plane of each studied metacarpal. The 3D images were converted to sagittal and coronal weighted projections to represent lateral and posteroanterior (PA) 2D images that are equivalent to "perfect orthogonal" radiographs. Using a customized image measurement program, shaft lengths, shaft-bending angle (SBA), and capital-axis angle (CAA) were measured. Results: Our results show that CAA averaged 14 and 12° in the ring and small metacarpals, respectively. Apex dorsal SBA averaged 12 and 10° in the ring and small metacarpals, respectively. On the PA images, the shafts are nearly straight. In contrast to prior reported values, we found the CAA to be less acute and the metacarpal curvature less pronounced on the lateral projection. We also demonstrated that much of the metacarpal apex dorsal bend is in the shaft itself. Conclusion: Normal anatomic parameters of metacarpals are based primarily onBackground: To date, only plain radiographic definitions of normal anatomical parameters have been described. Our study aims to describe normal anatomic measurements of small and ring metacarpals using a novel digital reconstruction technique based on raw CT image data. We hypothesize that current plain radiographic data incorrectly describes normal metacarpal anatomy in the lateral plane. Methods: Thirty-five scans of the small and 30 scans of the ring metacarpals form the basis for this study. Using a custom digital 3D image reformatting software, CT sections were reconstructed in the plane of each studied metacarpal. The 3D images were converted to sagittal and coronal weighted projections to represent lateral and posteroanterior (PA) 2D images that are equivalent to "perfect orthogonal" radiographs. Using a customized image measurement program, shaft lengths, shaft-bending angle (SBA), and capital-axis angle (CAA) were measured. Results: Our results show that CAA averaged 14 and 12° in the ring and small metacarpals, respectively. Apex dorsal SBA averaged 12 and 10° in the ring and small metacarpals, respectively. On the PA images, the shafts are nearly straight. In contrast to prior reported values, we found the CAA to be less acute and the metacarpal curvature less pronounced on the lateral projection. We also demonstrated that much of the metacarpal apex dorsal bend is in the shaft itself. Conclusion: Normal anatomic parameters of metacarpals are based primarily on radiographic data, and as such are limited due to bony overlap in the lateral plane, as well as imperfect radiographic projections that are known to distort anatomical relationships. This novel method of image reconstruction eliminates metacarpal overlap and defines precise anatomical reference for metacarpals. … (more)
- Is Part Of:
- Hand. Volume 10:Number 3(2015)
- Journal:
- Hand
- Issue:
- Volume 10:Number 3(2015)
- Issue Display:
- Volume 10, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 10
- Issue:
- 4
- Issue Sort Value:
- 2015-0010-0004-0000
- Page Start:
- 756
- Page End:
- 761
- Publication Date:
- 2015-12
- Subjects:
- Metacarpal anatomy -- Metacarpal overlap -- Metacarpal neck -- 3D CT -- Metacarpal imaging
Hand -- Surgery -- Periodicals
Hand -- Surgery
Periodicals
617.57005 - Journal URLs:
- http://www.springerlink.com/content/119980/ ↗
http://journals.sagepub.com/toc/HAN/current ↗
http://www.springer.com/gb/ ↗ - DOI:
- 10.1007/s11552-015-9766-7 ↗
- Languages:
- English
- ISSNs:
- 1558-9447
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4241.550050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6500.xml