Assessment of the clinical benefits of remote monitoring of cardiac‐implanted devices: A single‐center study in Japan. Issue 1 (24th August 2012)
- Record Type:
- Journal Article
- Title:
- Assessment of the clinical benefits of remote monitoring of cardiac‐implanted devices: A single‐center study in Japan. Issue 1 (24th August 2012)
- Main Title:
- Assessment of the clinical benefits of remote monitoring of cardiac‐implanted devices: A single‐center study in Japan
- Authors:
- Togo, Konomi
Takagi, Masahiko
Suzuki, Kentaro
Maeda, Keiko
Tatsumi, Hiroaki
Takeuchi, Kazuhide - Abstract:
- Abstract: Introduction: The clinical benefits of remote monitoring (RM) of cardiac‐implanted devices have not been fully evaluated in Japan. We investigated the clinical benefits of RM in a single center in Japan. Methods: Patients with pacemakers, implantable cardioverter‐defibrillators (ICD), or cardiac resynchronization therapy with defibrillators (CRT‐D) were assigned to RM and non‐RM groups. The outpatient wait times and times to notification of EVENTS that we defined sustained ventricular tachyarrhythmias, worsening heart failure, and inappropriate therapy for supraventricular tachyarrhythmias in this study, were compared between the 2 groups. Results: A total of 416 patients (RM: 61; non‐RM: 355) were evaluated. The outpatient wait time was 17.6±22.1 min for the RM group and 35.6±25.2 min for the non‐RM group ( P <0.001). Seventy‐seven and 306 EVENTS were observed in 38 and 256 patients during mean follow‐up periods of 360±22 days and 429±10 days in the RM and non‐RM groups, respectively. The times to notification of EVENTS were 8.1±16.2 days for the RM group and 38.7±33.2 days for the non‐RM group ( P <0.001). Conclusions: RM significantly shortened outpatient wait times and times to notification of EVENTS. Therefore, RM was clinically beneficial in a single center in Japan.
- Is Part Of:
- Journal of arrhythmia. Volume 29:Issue 1(2013)
- Journal:
- Journal of arrhythmia
- Issue:
- Volume 29:Issue 1(2013)
- Issue Display:
- Volume 29, Issue 1 (2013)
- Year:
- 2013
- Volume:
- 29
- Issue:
- 1
- Issue Sort Value:
- 2013-0029-0001-0000
- Page Start:
- 13
- Page End:
- 19
- Publication Date:
- 2012-08-24
- Subjects:
- Pacemaker -- Implantable cardioverter‐defibrillator -- Cardiac resynchronization therapy -- Remote device follow‐up
Arrhythmia -- Periodicals
Cardiac pacing -- Periodicals
Arrhythmias, Cardiac
Arrhythmia
Cardiac pacing
Periodicals
Electronic journals
Periodicals
616.128 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1883-2148/issues ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1016/j.joa.2012.06.001 ↗
- Languages:
- English
- ISSNs:
- 1880-4276
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6494.xml