Accuracy of device landing zone calcium volume measurement with contrast-enhanced multidetector computed tomography. (15th July 2018)
- Record Type:
- Journal Article
- Title:
- Accuracy of device landing zone calcium volume measurement with contrast-enhanced multidetector computed tomography. (15th July 2018)
- Main Title:
- Accuracy of device landing zone calcium volume measurement with contrast-enhanced multidetector computed tomography
- Authors:
- Kim, Won-Keun
Renker, Matthias
Rolf, Andreas
Liebetrau, Christoph
Van Linden, Arnaud
Arsalan, Mani
Doss, Mirko
Rieck, Julian
Opolski, Maksymilian P.
Möllmann, Helge
Walther, Thomas
Hamm, Christian W. - Abstract:
- Abstract: Background: The extent of aortic valve calcification is an important determinant of procedural success in transcatheter aortic valve implantation (TAVI). We sought to validate device landing zone calcium volume (DLZ-CV) measurements on contrast-enhanced multidetector computed tomography (MDCT) with non-contrast-enhanced scans as reference. Methods: We determined DLZ-CV in 141 patients undergoing transfemoral TAVI. Non-contrast-enhanced images were analyzed using a threshold of 130 HU as reference (DLZ-CV130 ). For contrast-enhanced scans, we applied various thresholds including 450 HU (DLZ-CV450 ), 850 HU (DLZ-CV850 ), mean aortic attenuation (AttenAo ) + 2 SD (DLZ-CV2SD ), AttenAo + 4 SD (DLZ-CV4SD ), AttenAo + 4 SD + 5 mm 3 volume filter (DLZ-CV4SD+ ), and based on visual estimation (DLZ-CVvis ). We compared DLZ-CV values between patients with versus without paravalvular leak (PVL), and between patients with versus without post-dilatation stratified by the type of prosthesis. Results: All DLZ-CV measurements on contrast-enhanced scans significantly differed from DLZ-CV130 (p < 0.001 for all comparisons). The best approximation to DLZ-CV130 was achieved with DLZ-CV4SD+ (508 mm 3 [332–772]; Pearson correlation: R = 0.87, p < 0.001; Bland-Altman: mean difference 1339 mm 3 [limits of agreement 79;2600]). Moreover, DLZ-CV4SD+ allowed for discrimination of PVL ≥1° or the need for post-dilatation in patients receiving self-expanding prostheses. Procedural outcomeAbstract: Background: The extent of aortic valve calcification is an important determinant of procedural success in transcatheter aortic valve implantation (TAVI). We sought to validate device landing zone calcium volume (DLZ-CV) measurements on contrast-enhanced multidetector computed tomography (MDCT) with non-contrast-enhanced scans as reference. Methods: We determined DLZ-CV in 141 patients undergoing transfemoral TAVI. Non-contrast-enhanced images were analyzed using a threshold of 130 HU as reference (DLZ-CV130 ). For contrast-enhanced scans, we applied various thresholds including 450 HU (DLZ-CV450 ), 850 HU (DLZ-CV850 ), mean aortic attenuation (AttenAo ) + 2 SD (DLZ-CV2SD ), AttenAo + 4 SD (DLZ-CV4SD ), AttenAo + 4 SD + 5 mm 3 volume filter (DLZ-CV4SD+ ), and based on visual estimation (DLZ-CVvis ). We compared DLZ-CV values between patients with versus without paravalvular leak (PVL), and between patients with versus without post-dilatation stratified by the type of prosthesis. Results: All DLZ-CV measurements on contrast-enhanced scans significantly differed from DLZ-CV130 (p < 0.001 for all comparisons). The best approximation to DLZ-CV130 was achieved with DLZ-CV4SD+ (508 mm 3 [332–772]; Pearson correlation: R = 0.87, p < 0.001; Bland-Altman: mean difference 1339 mm 3 [limits of agreement 79;2600]). Moreover, DLZ-CV4SD+ allowed for discrimination of PVL ≥1° or the need for post-dilatation in patients receiving self-expanding prostheses. Procedural outcome using balloon-expandable prostheses was independent of DLZ-CV. Conclusion: Measurement of DLZ-CV using contrast-enhanced scans with unadjusted thresholds results in incorrect estimation of the calcium volume. The use of a scan-specific individual HU threshold including a volume filter (DLZ-CV4SD+ ) provides the best approximation to the reference and allows for discrimination of PVL ≥ 1° in patients receiving the Acurate neo prosthesis. Highlights: Measuring DLZ-CV on contrast-enhanced scans with unadjusted thresholds is inaccurate. Scan-specific individual HU-thresholds provide the best approximation to the Agatston method. DLZ-CV discriminates PVL ≥ 1° when using the self-expanding Acurate neo device. PVL is independent of DLZ-CV for the balloon-expandable Sapien 3 device. … (more)
- Is Part Of:
- International journal of cardiology. Volume 263(2018)
- Journal:
- International journal of cardiology
- Issue:
- Volume 263(2018)
- Issue Display:
- Volume 263, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 263
- Issue:
- 2018
- Issue Sort Value:
- 2018-0263-2018-0000
- Page Start:
- 171
- Page End:
- 176
- Publication Date:
- 2018-07-15
- Subjects:
- AVCV aortic valve calcium volume -- DLZ-CV device landing zone calcium volume -- DLZ-CV130 DLZ-CV with threshold at 130 HU on non-contrast-enhanced scans -- DLZ-CVvis DLZ-CV with visually adjusted threshold -- DLZ-CV450 DLZ-CV with threshold at 450 HU -- DLZ-CV850 DLZ-CV with threshold at 850 HU -- DLZ-CV2SD DLZ-CV with threshold determined according to aortic attenuation +2 SD -- DLZ-CV4SD DLZ-CV with threshold determined according to aortic attenuation +4 SD -- DLZ-CV4SD+ DLZ-CV with threshold determined according to aortic attenuation +4 SD and additional volume filter set at 5 mm3 -- HU Hounsfield Unit -- MDCT multidetector computed tomography -- LVOT-CV left ventricular outflow tract calcium volume -- PVL paravalvular leak -- TAVI transcatheter aortic valve implantation
Aortic stenosis -- TAVI -- TAVR -- MDCT -- Calcium score
Cardiology -- Periodicals
Electronic journals
616.12 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/01675273 ↗
http://www.sciencedirect.com/science/journal/01675273 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijcard.2018.02.042 ↗
- Languages:
- English
- ISSNs:
- 0167-5273
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.158000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6481.xml