Model-based iterative reconstruction and adaptive statistical iterative reconstruction: dose-reduced CT for detecting pancreatic calcification. (22nd January 2016)
- Record Type:
- Journal Article
- Title:
- Model-based iterative reconstruction and adaptive statistical iterative reconstruction: dose-reduced CT for detecting pancreatic calcification. (22nd January 2016)
- Main Title:
- Model-based iterative reconstruction and adaptive statistical iterative reconstruction: dose-reduced CT for detecting pancreatic calcification
- Authors:
- Yasaka, Koichiro
Katsura, Masaki
Akahane, Masaaki
Sato, Jiro
Matsuda, Izuru
Ohtomo, Kuni - Abstract:
- Background: Iterative reconstruction methods have attracted attention for reducing radiation doses in computed tomography (CT). Purpose: To investigate the detectability of pancreatic calcification using dose-reduced CT reconstructed with model-based iterative construction (MBIR) and adaptive statistical iterative reconstruction (ASIR). Material and Methods: This prospective study approved by Institutional Review Board included 85 patients (57 men, 28 women; mean age, 69.9 years; mean body weight, 61.2 kg). Unenhanced CT was performed three times with different radiation doses (reference-dose CT [RDCT], low-dose CT [LDCT], ultralow-dose CT [ULDCT]). From RDCT, LDCT, and ULDCT, images were reconstructed with filtered-back projection (R-FBP, used for establishing reference standard), ASIR (L-ASIR), and MBIR and ASIR (UL-MBIR and UL-ASIR), respectively. A lesion (pancreatic calcification) detection test was performed by two blinded radiologists with a five-point certainty level scale. Results: Dose-length products of RDCT, LDCT, and ULDCT were 410, 97, and 36 mGy-cm, respectively. Nine patients had pancreatic calcification. The sensitivity for detecting pancreatic calcification with UL-MBIR was high (0.67–0.89) compared to L-ASIR or UL-ASIR (0.11–0.44), and a significant difference was seen between UL-MBIR and UL-ASIR for one reader ( P = 0.014). The area under the receiver-operating characteristic curve for UL-MBIR (0.818–0.860) was comparable to that for L-ASIRBackground: Iterative reconstruction methods have attracted attention for reducing radiation doses in computed tomography (CT). Purpose: To investigate the detectability of pancreatic calcification using dose-reduced CT reconstructed with model-based iterative construction (MBIR) and adaptive statistical iterative reconstruction (ASIR). Material and Methods: This prospective study approved by Institutional Review Board included 85 patients (57 men, 28 women; mean age, 69.9 years; mean body weight, 61.2 kg). Unenhanced CT was performed three times with different radiation doses (reference-dose CT [RDCT], low-dose CT [LDCT], ultralow-dose CT [ULDCT]). From RDCT, LDCT, and ULDCT, images were reconstructed with filtered-back projection (R-FBP, used for establishing reference standard), ASIR (L-ASIR), and MBIR and ASIR (UL-MBIR and UL-ASIR), respectively. A lesion (pancreatic calcification) detection test was performed by two blinded radiologists with a five-point certainty level scale. Results: Dose-length products of RDCT, LDCT, and ULDCT were 410, 97, and 36 mGy-cm, respectively. Nine patients had pancreatic calcification. The sensitivity for detecting pancreatic calcification with UL-MBIR was high (0.67–0.89) compared to L-ASIR or UL-ASIR (0.11–0.44), and a significant difference was seen between UL-MBIR and UL-ASIR for one reader ( P = 0.014). The area under the receiver-operating characteristic curve for UL-MBIR (0.818–0.860) was comparable to that for L-ASIR (0.696–0.844). The specificity was lower with UL-MBIR (0.79–0.92) than with L-ASIR or UL-ASIR (0.96–0.99), and a significant difference was seen for one reader ( P < 0.01). Conclusion: In UL-MBIR, pancreatic calcification can be detected with high sensitivity, however, we should pay attention to the slightly lower specificity. … (more)
- Is Part Of:
- Acta radiologica open. Volume 5:Number 1(2016)
- Journal:
- Acta radiologica open
- Issue:
- Volume 5:Number 1(2016)
- Issue Display:
- Volume 5, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 5
- Issue:
- 1
- Issue Sort Value:
- 2016-0005-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-01-22
- Subjects:
- Abdomen/GI -- computed tomography (CT) -- pancreas -- calcifications/calculi -- adults -- observer performance
Radiology -- Periodicals
Diagnostic Imaging -- Periodicals
Radiology
Periodicals
616.075705 - Journal URLs:
- http://arr.sagepub.com/ ↗
http://arr.sagepub.com/ ↗
http://www.uk.sagepub.com ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/2704/ ↗ - DOI:
- 10.1177/2058460116628340 ↗
- Languages:
- English
- ISSNs:
- 2058-4601
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6476.xml