Can FLAIR hyperintense vessel (FHV) signs be influenced by varying MR parameters and flow velocities? A flow phantom analysis. (May 2016)
- Record Type:
- Journal Article
- Title:
- Can FLAIR hyperintense vessel (FHV) signs be influenced by varying MR parameters and flow velocities? A flow phantom analysis. (May 2016)
- Main Title:
- Can FLAIR hyperintense vessel (FHV) signs be influenced by varying MR parameters and flow velocities? A flow phantom analysis
- Authors:
- Ahn, Sung Jun
Lee, Kyung-Yul
Ahn, Sung Soo
Suh, Hwal
Kim, Bum-soo
Lee, Seung-Koo - Abstract:
- Background: Fluid-attenuated inversion recovery (FLAIR) hyperintense vessels (FHVs) have been used to assess leptomeningeal collateral flow in acute ischemic stroke. However, prior FHVs studies showed inconsistent results, which may be ascribable to different magnetic resonance (MR) parameters used. Purpose: To evaluate whether FHVs could be influenced by varying MR parameters and flow velocities, using a flow phantom. Material and Methods: A total of 512 sets of FLAIRs were performed with varying parameters and flow velocities, using a flow phantom. Flow phantom was manufactured with 3.5% agarose solution, an 8-mm inner diameter silicone tube and non-pulsatile pump. Varying MR parameters were repetition time (TR)/inversion time (TI), echo time (TE), flip angle (FA) of refocusing pulse, and periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER). The signal intensity of flow were measured and regarded as the degree of FHVs. Simple and multiple linear regression analyses were applied to evaluate the association between the degree of FHVs and varying MR parameters as well as flow velocities. Results: On univariate analysis, PROPELLER technique (R 2 = 0.448) demonstrated strongest correlation with the degree of FHV, followed by flow velocities (R 2 = 0.204), FA (R 2 = 0.126), and TE (R 2 = 0.031), whereas TR/TI showed no significant correlations. On multivariate analysis, TE, FA, PROPELLER technique, and flow velocities were independentBackground: Fluid-attenuated inversion recovery (FLAIR) hyperintense vessels (FHVs) have been used to assess leptomeningeal collateral flow in acute ischemic stroke. However, prior FHVs studies showed inconsistent results, which may be ascribable to different magnetic resonance (MR) parameters used. Purpose: To evaluate whether FHVs could be influenced by varying MR parameters and flow velocities, using a flow phantom. Material and Methods: A total of 512 sets of FLAIRs were performed with varying parameters and flow velocities, using a flow phantom. Flow phantom was manufactured with 3.5% agarose solution, an 8-mm inner diameter silicone tube and non-pulsatile pump. Varying MR parameters were repetition time (TR)/inversion time (TI), echo time (TE), flip angle (FA) of refocusing pulse, and periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER). The signal intensity of flow were measured and regarded as the degree of FHVs. Simple and multiple linear regression analyses were applied to evaluate the association between the degree of FHVs and varying MR parameters as well as flow velocities. Results: On univariate analysis, PROPELLER technique (R 2 = 0.448) demonstrated strongest correlation with the degree of FHV, followed by flow velocities (R 2 = 0.204), FA (R 2 = 0.126), and TE (R 2 = 0.031), whereas TR/TI showed no significant correlations. On multivariate analysis, TE, FA, PROPELLER technique, and flow velocities were independent factors influencing the degree of FHVs (<0.001). Conclusion: Flow velocities, FA of refocusing pulse, TE, and PROPELLER technique significantly affected the degree of FHVs. Optimized MR parameters should be used consistently in future studies, which may provide more reliable results. … (more)
- Is Part Of:
- Acta radiologica. Volume 57:Number 5(2016:May)
- Journal:
- Acta radiologica
- Issue:
- Volume 57:Number 5(2016:May)
- Issue Display:
- Volume 57, Issue 5 (2016)
- Year:
- 2016
- Volume:
- 57
- Issue:
- 5
- Issue Sort Value:
- 2016-0057-0005-0000
- Page Start:
- 580
- Page End:
- 586
- Publication Date:
- 2016-05
- Subjects:
- Stroke -- collateral circulation -- magnetic resonance imaging (MRI) -- FLAIR -- flow phantom
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1177/0284185115592060 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6474.xml