Endoscopic closure of persistent gastrocutaneous fistulae, after percutaneous endoscopic gastrostomy (PEG) tube placement, using the over-the-scope-clip system. (July 2015)
- Record Type:
- Journal Article
- Title:
- Endoscopic closure of persistent gastrocutaneous fistulae, after percutaneous endoscopic gastrostomy (PEG) tube placement, using the over-the-scope-clip system. (July 2015)
- Main Title:
- Endoscopic closure of persistent gastrocutaneous fistulae, after percutaneous endoscopic gastrostomy (PEG) tube placement, using the over-the-scope-clip system
- Authors:
- Singhal, Shashideep
Changela, Kinesh
Culliford, Andrea
Duddempudi, Sushil
Krishnaiah, Mahesh
Anand, Sury - Abstract:
- Objectives: The Over-The-Scope-Clip (OTSC) has had an evolving role in endoscopic closure of gastrointestinal wall defects, in hemostasis of primary or postinterventional bleeding, and approximation of postbariatric surgery defects. Rapid and effective closure of gastrocutaneous (GC) fistulae using this device has been recently described in the literature. The aim of this study was to evaluate the technical feasibility, efficacy and safety of OTSC as an effective tool in the management of persistent GC fistulae secondary to a complication of percutaneous endoscopic gastrostomy (PEG) tube placement. Method: In this multicenter prospective observational study, we describe our experience with OTSC in the closure of persistent GC fistulas secondary to PEG tube placement. Patients with GC fistulas were sequentially enrolled with a mean age of 84 years. Primary treatment outcome was the immediate successful closure of GC fistula and resolution of leak. Secondary outcome was no recurrence of the fistula and leaks on follow up. Results: A total of 10 patients were enrolled over the study period. Mean age was 84.4 ± 8.75 years. The primary treatment outcome was achieved in all the patients undergoing this intervention. Secondary outcome was observed in 9/10 (90%) subjects. No procedural complications were reported. Larger fistulae (>2.5 cm) and those with significant fibrosis were more difficult to close with the OTSC system. The mean follow-up time after OTSC application was 43.7 ±Objectives: The Over-The-Scope-Clip (OTSC) has had an evolving role in endoscopic closure of gastrointestinal wall defects, in hemostasis of primary or postinterventional bleeding, and approximation of postbariatric surgery defects. Rapid and effective closure of gastrocutaneous (GC) fistulae using this device has been recently described in the literature. The aim of this study was to evaluate the technical feasibility, efficacy and safety of OTSC as an effective tool in the management of persistent GC fistulae secondary to a complication of percutaneous endoscopic gastrostomy (PEG) tube placement. Method: In this multicenter prospective observational study, we describe our experience with OTSC in the closure of persistent GC fistulas secondary to PEG tube placement. Patients with GC fistulas were sequentially enrolled with a mean age of 84 years. Primary treatment outcome was the immediate successful closure of GC fistula and resolution of leak. Secondary outcome was no recurrence of the fistula and leaks on follow up. Results: A total of 10 patients were enrolled over the study period. Mean age was 84.4 ± 8.75 years. The primary treatment outcome was achieved in all the patients undergoing this intervention. Secondary outcome was observed in 9/10 (90%) subjects. No procedural complications were reported. Larger fistulae (>2.5 cm) and those with significant fibrosis were more difficult to close with the OTSC system. The mean follow-up time after OTSC application was 43.7 ± 20.57 days. A limitation of this study was that there was no control group. Conclusions: OTSC application is a safe and effective endoscopic approach for the closure of persistent GC fistulae secondary to a complication of PEG tube placement. … (more)
- Is Part Of:
- Therapeutic advances in gastroenterology. Volume 8:Number 4(2015:Jul.)
- Journal:
- Therapeutic advances in gastroenterology
- Issue:
- Volume 8:Number 4(2015:Jul.)
- Issue Display:
- Volume 8, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 8
- Issue:
- 4
- Issue Sort Value:
- 2015-0008-0004-0000
- Page Start:
- 182
- Page End:
- 188
- Publication Date:
- 2015-07
- Subjects:
- endoscopic closure -- gastrocutaneous fistula -- OTSC -- Over-the-Scope-Clip
Gastroenterology -- Periodicals
Digestive organs -- Diseases -- Treatment -- Periodicals
Gastrointestinal system -- Diseases -- Treatment -- Periodicals
Liver -- Diseases -- Treatment -- Periodicals
Pharmacology -- Periodicals
Gastroenterology -- Periodicals
Gastrointestinal Diseases -- therapy -- Periodicals
Liver Diseases -- therapy -- Periodicals
Pharmacology -- Periodicals
Gastroentérologie -- Périodiques
Appareil digestif -- Maladies -- Traitement -- Périodiques
Tractus gastro-intestinal -- Maladies -- Traitement -- Périodiques
Hépatologie -- Périodiques
Foie -- Maladies -- Périodiques
Pharmacologie -- Périodiques
616.3005 - Journal URLs:
- http://rave.ohiolink.edu/ejournals/issn/1756283x/ ↗
http://tag.sagepub.com/ ↗
http://www.uk.sagepub.com/home.nav ↗
http://www.tag.sagepub.com/ ↗ - DOI:
- 10.1177/1756283X15578603 ↗
- Languages:
- English
- ISSNs:
- 1756-283X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6456.xml