Evaluation of postural steadiness in below-knee amputees when wearing different prosthetic feet during various sensory conditions using the Biodex® Stability System. (July 2015)
- Record Type:
- Journal Article
- Title:
- Evaluation of postural steadiness in below-knee amputees when wearing different prosthetic feet during various sensory conditions using the Biodex® Stability System. (July 2015)
- Main Title:
- Evaluation of postural steadiness in below-knee amputees when wearing different prosthetic feet during various sensory conditions using the Biodex® Stability System
- Authors:
- Arifin, Nooranida
Abu Osman, Noor Azuan
Ali, Sadeeq
Gholizadeh, Hossein
Wan Abas, Wan Abu Bakar - Abstract:
- In recent years, computerized posturography has become an essential tool in quantitative assessment of postural steadiness in the clinical settings. The purpose of this study was to explore the ability of the Biodex ® Stability System (BSS) to quantify postural steadiness in below-knee amputees. A convenience sample of 10 below-knee amputees participated in the study. The overall (OSI), anterior–posterior (APSI) and medial–lateral (MLSI) stability indexes as well as the percentage of time spent in left and right quadrants and four concentric zones were measured under altered sensory conditions while standing with solid ankle cushion heel (SACH), single-axis (SA) and energy storage and release (ESAR) feet. Significant difference was found between sensory conditions in SACH and ESAR feet for OSI (SACH, p = 0.002; ESAR, p = 0.005), APSI (SACH, p = 0.036; ESAR, p = 0.003) and MLSI (SACH, p = 0.008; ESAR, p = 0.05) stability indexes. The percentage of time spent in Zone A (0°–5°) was significantly greater than the other three concentric zones (p < 0.01). The loading time percentage on their intact limb (80%–94%) was significantly longer than the amputated limb (20%–6%) in all conditions for all three prosthetic feet. Below-knee amputees showed compromised postural steadiness when visual, proprioceptive or vestibular sensory input was altered. The findings highlight that the characteristics of postural stability in amputees can be clinically assessed by utilizing the outcomesIn recent years, computerized posturography has become an essential tool in quantitative assessment of postural steadiness in the clinical settings. The purpose of this study was to explore the ability of the Biodex ® Stability System (BSS) to quantify postural steadiness in below-knee amputees. A convenience sample of 10 below-knee amputees participated in the study. The overall (OSI), anterior–posterior (APSI) and medial–lateral (MLSI) stability indexes as well as the percentage of time spent in left and right quadrants and four concentric zones were measured under altered sensory conditions while standing with solid ankle cushion heel (SACH), single-axis (SA) and energy storage and release (ESAR) feet. Significant difference was found between sensory conditions in SACH and ESAR feet for OSI (SACH, p = 0.002; ESAR, p = 0.005), APSI (SACH, p = 0.036; ESAR, p = 0.003) and MLSI (SACH, p = 0.008; ESAR, p = 0.05) stability indexes. The percentage of time spent in Zone A (0°–5°) was significantly greater than the other three concentric zones (p < 0.01). The loading time percentage on their intact limb (80%–94%) was significantly longer than the amputated limb (20%–6%) in all conditions for all three prosthetic feet. Below-knee amputees showed compromised postural steadiness when visual, proprioceptive or vestibular sensory input was altered. The findings highlight that the characteristics of postural stability in amputees can be clinically assessed by utilizing the outcomes produced by the BSS. … (more)
- Is Part Of:
- Proceedings of the Institution of Mechanical Engineers. Volume 229:Number 7(2015:Jul.)
- Journal:
- Proceedings of the Institution of Mechanical Engineers
- Issue:
- Volume 229:Number 7(2015:Jul.)
- Issue Display:
- Volume 229, Issue 7 (2015)
- Year:
- 2015
- Volume:
- 229
- Issue:
- 7
- Issue Sort Value:
- 2015-0229-0007-0000
- Page Start:
- 491
- Page End:
- 498
- Publication Date:
- 2015-07
- Subjects:
- Amputees -- Biodex Stability System -- postural balance -- prosthesis -- rehabilitation
Biomedical engineering -- Periodicals
Medical instruments and apparatus -- Periodicals
610.28 - Journal URLs:
- http://pih.sagepub.com/ ↗
http://journals.pepublishing.com/content/119779 ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/0954411915587595 ↗
- Languages:
- English
- ISSNs:
- 0954-4119
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6453.xml