Flammable vapor cloud generation from overfilling tanks: Learning the lessons from Buncefield. (May 2015)
- Record Type:
- Journal Article
- Title:
- Flammable vapor cloud generation from overfilling tanks: Learning the lessons from Buncefield. (May 2015)
- Main Title:
- Flammable vapor cloud generation from overfilling tanks: Learning the lessons from Buncefield
- Authors:
- Atkinson, Graham
Coldrick, Simon
Gant, Simon
Cusco, Laurence - Abstract:
- Abstract: The Buncefield Incident in 2005 led to a significant change in our understanding of how flammable vapor clouds could be generated from overfilling bulk storage tanks with volatile liquids. Prior to that incident, it was widely thought that an overfilling tank would produce a pool of liquid in the bunded area around a tank that would evaporate relatively slowly. However, in the Buncefield Incident, the release of liquid through vents in the tank roof led to waterfall-like cascade of fine gasoline droplets that produced flammable vapor at a much faster rate. It took only around 25 min for the dense current of flammable vapor to fill an area roughly 500 m by 400 m to a depth of between 2 m and 4 m. The wind speed was very low during the incident and the way in which the vapor cloud dispersed was affected by the slope of the ground and presence of obstacles. The resulting explosion was severe, even across open unobstructed areas. Fortunately there were no fatalities, but the total damage from the incident was estimated to have cost around $1.5 billion. Since the Buncefield Incident took place, several incidents with striking similarities have taken place at Jaipur (India), San Juan (Puerto Rico) and the Amuay Refinery (Venezuela). This paper presents the findings of the Buncefield Incident investigation team and further research that has been carried out on tank overfilling releases over the last seven years at the Health and Safety Laboratory (HSL). The work hasAbstract: The Buncefield Incident in 2005 led to a significant change in our understanding of how flammable vapor clouds could be generated from overfilling bulk storage tanks with volatile liquids. Prior to that incident, it was widely thought that an overfilling tank would produce a pool of liquid in the bunded area around a tank that would evaporate relatively slowly. However, in the Buncefield Incident, the release of liquid through vents in the tank roof led to waterfall-like cascade of fine gasoline droplets that produced flammable vapor at a much faster rate. It took only around 25 min for the dense current of flammable vapor to fill an area roughly 500 m by 400 m to a depth of between 2 m and 4 m. The wind speed was very low during the incident and the way in which the vapor cloud dispersed was affected by the slope of the ground and presence of obstacles. The resulting explosion was severe, even across open unobstructed areas. Fortunately there were no fatalities, but the total damage from the incident was estimated to have cost around $1.5 billion. Since the Buncefield Incident took place, several incidents with striking similarities have taken place at Jaipur (India), San Juan (Puerto Rico) and the Amuay Refinery (Venezuela). This paper presents the findings of the Buncefield Incident investigation team and further research that has been carried out on tank overfilling releases over the last seven years at the Health and Safety Laboratory (HSL). The work has involved a combination of unique spill experiments and Computational Fluid Dynamics (CFD) modeling, and has resulted in a simple methodology for predicting the rate of flammable vapor production from overfilling tanks. This paper takes the opportunity to present for the first time a unified narrative, starting with the key findings of the incident investigation and culminating with the description of a workbook method for predicting which substances and storage tanks could create significant vapor clouds. Highlights: The mechanisms responsible for generation and dispersion of flammable vapor from overfilling tanks are examined. The Buncefield incident investigation and subsequent research at HSL are summarized. A method for predicting which substances and storage tanks could create significant vapor clouds is described. … (more)
- Is Part Of:
- Journal of loss prevention in the process industries. Volume 35(2015:May)
- Journal:
- Journal of loss prevention in the process industries
- Issue:
- Volume 35(2015:May)
- Issue Display:
- Volume 35 (2015)
- Year:
- 2015
- Volume:
- 35
- Issue Sort Value:
- 2015-0035-0000-0000
- Page Start:
- 329
- Page End:
- 338
- Publication Date:
- 2015-05
- Subjects:
- Buncefield incident -- Tank overfilling -- Vapor generation -- Dispersion -- CFD
Chemical industries -- Safety measures -- Periodicals
660.2804 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09504230/ ↗
http://www.journals.elsevier.com/journal-of-loss-prevention-in-the-process-industries/ ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jlp.2014.11.011 ↗
- Languages:
- English
- ISSNs:
- 0950-4230
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.562000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6445.xml