A study of whether automated Diabetic Retinopathy Image Assessment could replace manual grading steps in the English National Screening Programme. (September 2015)
- Record Type:
- Journal Article
- Title:
- A study of whether automated Diabetic Retinopathy Image Assessment could replace manual grading steps in the English National Screening Programme. (September 2015)
- Main Title:
- A study of whether automated Diabetic Retinopathy Image Assessment could replace manual grading steps in the English National Screening Programme
- Authors:
- Kapetanakis, Venediktos V
Rudnicka, Alicja R
Liew, Gerald
Owen, Christopher G
Lee, Aaron
Louw, Vern
Bolter, Louis
Anderson, John
Egan, Catherine
Salas-Vega, Sebastian
Rudisill, Caroline
Taylor, Paul
Tufail, Adnan - Abstract:
- Objectives: Diabetic retinopathy screening in England involves labour intensive manual grading of digital retinal images. We present the plan for an observational retrospective study of whether automated systems could replace one or more steps of human grading. Methods: Patients aged 12 or older who attended the Diabetes Eye Screening programme, Homerton University Hospital (London) between 1 June 2012 and 4 November 2013 had macular and disc-centred retinal images taken. All screening episodes were manually graded and will additionally be graded by three automated systems. Each system will process all screening episodes, and screening performance (sensitivity, false positive rate, likelihood ratios) and diagnostic accuracy (95% confidence intervals of screening performance measures) will be quantified. A sub-set of gradings will be validated by an approved Reading Centre. Additional analyses will explore the effect of altering thresholds for disease detection within each automated system on screening performance. Results: 2, 782/20, 258 diabetes patients were referred to ophthalmologists for further examination. Prevalence of maculopathy (M1), pre-proliferative retinopathy (R2), and proliferative retinopathy (R3) were 7.9%, 3.1% and 1.2%, respectively; 4749 (23%) patients were diagnosed with background retinopathy (R1); 1.5% were considered ungradable by human graders. Conclusions: Retinopathy prevalence was similar to other English diabetic screening programmes, soObjectives: Diabetic retinopathy screening in England involves labour intensive manual grading of digital retinal images. We present the plan for an observational retrospective study of whether automated systems could replace one or more steps of human grading. Methods: Patients aged 12 or older who attended the Diabetes Eye Screening programme, Homerton University Hospital (London) between 1 June 2012 and 4 November 2013 had macular and disc-centred retinal images taken. All screening episodes were manually graded and will additionally be graded by three automated systems. Each system will process all screening episodes, and screening performance (sensitivity, false positive rate, likelihood ratios) and diagnostic accuracy (95% confidence intervals of screening performance measures) will be quantified. A sub-set of gradings will be validated by an approved Reading Centre. Additional analyses will explore the effect of altering thresholds for disease detection within each automated system on screening performance. Results: 2, 782/20, 258 diabetes patients were referred to ophthalmologists for further examination. Prevalence of maculopathy (M1), pre-proliferative retinopathy (R2), and proliferative retinopathy (R3) were 7.9%, 3.1% and 1.2%, respectively; 4749 (23%) patients were diagnosed with background retinopathy (R1); 1.5% were considered ungradable by human graders. Conclusions: Retinopathy prevalence was similar to other English diabetic screening programmes, so findings should be generalizable. The study population size will allow the detection of differences in screening performance between the human and automated grading systems as small as 2%. The project will compare performance and economic costs of manual versus automated systems. … (more)
- Is Part Of:
- Journal of medical screening. Volume 22:Number 3(2015)
- Journal:
- Journal of medical screening
- Issue:
- Volume 22:Number 3(2015)
- Issue Display:
- Volume 22, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 22
- Issue:
- 3
- Issue Sort Value:
- 2015-0022-0003-0000
- Page Start:
- 112
- Page End:
- 118
- Publication Date:
- 2015-09
- Subjects:
- Medical screening -- Periodicals
362.177 - Journal URLs:
- https://journals.sagepub.com/home/msca ↗
http://jms.rsmjournals.com ↗
http://msc.sagepub.com ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/0969141315571953 ↗
- Languages:
- English
- ISSNs:
- 0969-1413
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6448.xml