Push-out test on the web opening shear connector for a slim-floor steel beam: Experimental and analytical study. (15th May 2018)
- Record Type:
- Journal Article
- Title:
- Push-out test on the web opening shear connector for a slim-floor steel beam: Experimental and analytical study. (15th May 2018)
- Main Title:
- Push-out test on the web opening shear connector for a slim-floor steel beam: Experimental and analytical study
- Authors:
- Hosseinpour, Emad
Baharom, Shahrizan
W. Badaruzzaman, Wan Hamidon
Al Zand, Ahmed W. - Abstract:
- Highlights: Varied shape of web opening (WO) shear connectors were tested using push-out test. Highest direct shear capacity was obtained using square web opening shear connector. Optimum spacings of WO shear connectors are between 250 mm and 300 mm. Establishment of equation to predict ultimate shear resistance of web opening shear connectors. Abstract: In slim-floor construction, the web opening of the steel beam is proposed as WO shear connectors of different shapes; square (WSO), rectangular (WRO) and circular (WCO) connectors were considered to evaluate the ultimate shear strength, failure mode and ductility performance. Six push-out tests were conducted under static loading. Finite Element (FE) models using ABAQUS software were validated using test results, and then, further models were developed. The effective parameters include web thickness of the steel beam, opening size, compressive strength of the concrete slab and group arrangement for WO connectors. The test result indicates higher shear strength for the WSO shear connector compared with WRO and WCO. FE analysis presents notable shear achievement of WSO and WRO connectors because of the larger effective width of the square and rectangular openings incorporated with infill concrete. Thicker web steel beam associated with larger opening enhanced the compressive and tensile resistance area of the infill concrete in all cases. The effective spacing between group WCO shear connectors was found to be 250 mm, and itHighlights: Varied shape of web opening (WO) shear connectors were tested using push-out test. Highest direct shear capacity was obtained using square web opening shear connector. Optimum spacings of WO shear connectors are between 250 mm and 300 mm. Establishment of equation to predict ultimate shear resistance of web opening shear connectors. Abstract: In slim-floor construction, the web opening of the steel beam is proposed as WO shear connectors of different shapes; square (WSO), rectangular (WRO) and circular (WCO) connectors were considered to evaluate the ultimate shear strength, failure mode and ductility performance. Six push-out tests were conducted under static loading. Finite Element (FE) models using ABAQUS software were validated using test results, and then, further models were developed. The effective parameters include web thickness of the steel beam, opening size, compressive strength of the concrete slab and group arrangement for WO connectors. The test result indicates higher shear strength for the WSO shear connector compared with WRO and WCO. FE analysis presents notable shear achievement of WSO and WRO connectors because of the larger effective width of the square and rectangular openings incorporated with infill concrete. Thicker web steel beam associated with larger opening enhanced the compressive and tensile resistance area of the infill concrete in all cases. The effective spacing between group WCO shear connectors was found to be 250 mm, and it was found to be 300 mm for WSO and WRO to achieve maximum shear strength. Finally, the ultimate shear resistance of the WCO and WSO/WRO shear connectors were predicted and validated with COV of 0.032 and 0.021, respectively. … (more)
- Is Part Of:
- Engineering structures. Volume 163(2018)
- Journal:
- Engineering structures
- Issue:
- Volume 163(2018)
- Issue Display:
- Volume 163, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 163
- Issue:
- 2018
- Issue Sort Value:
- 2018-0163-2018-0000
- Page Start:
- 137
- Page End:
- 152
- Publication Date:
- 2018-05-15
- Subjects:
- Slim-floor -- Web opening -- Shear connector -- Group effect -- Push-out test -- Shear strength
Structural engineering -- Periodicals
Structural analysis (Engineering) -- Periodicals
Construction, Technique de la -- Périodiques
Génie parasismique -- Périodiques
Pression du vent -- Périodiques
Earthquake engineering
Structural engineering
Wind-pressure
Periodicals
624.105 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01410296 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.engstruct.2018.02.047 ↗
- Languages:
- English
- ISSNs:
- 0141-0296
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3770.032000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6419.xml