Achieving interfragmentary compression without special drilling technique or screw design. Issue 4 (4th October 2017)
- Record Type:
- Journal Article
- Title:
- Achieving interfragmentary compression without special drilling technique or screw design. Issue 4 (4th October 2017)
- Main Title:
- Achieving interfragmentary compression without special drilling technique or screw design
- Authors:
- Eastman, Jonathan
Deafenbaugh, Bradley
Christiansen, Blaine
Garcia‐Nolen, Tanya
Lee, Mark - Abstract:
- ABSTRACT: Traditional fracture fixation teaching suggests that fully threaded screws do not provide interfragmentary compression unless placed through a glide hole. Based on this assumption, pelvic surgeons typically use fully threaded screws in the treatment of comminuted transforaminal sacral fractures to limit iatrogenic neuroforaminal stenosis. Clinical experience with fully threaded screws suggests that interfragmentary compression actually does occur. We hypothesized that the use of a fully threaded screw does not produce any interfragmentary compression and that there is no difference in insertional torque between partially threaded and fully threaded screws. To test this hypothesis, fully and partially threaded 7.0 millimeter (mm) cannulated screws were placed across two synthetic bone blocks fabricated to simulate normal and osteoporotic bone. We compared two groups of normal and osteoporotic blocks for compression achieved and maximal insertional torque generated with fully threaded and partially threaded screw insertion. A micro computed tomography (CT) scan of the composite blocks was obtained to investigate for structural changes created during screw insertion. For both groups, compression was achieved with fully threaded screws and the maximal insertional torque was higher using fully threaded screws. Micro CT analysis demonstrated local bone damage with structural disruption in the near segment of the fully threaded screw path in comparison to the partiallyABSTRACT: Traditional fracture fixation teaching suggests that fully threaded screws do not provide interfragmentary compression unless placed through a glide hole. Based on this assumption, pelvic surgeons typically use fully threaded screws in the treatment of comminuted transforaminal sacral fractures to limit iatrogenic neuroforaminal stenosis. Clinical experience with fully threaded screws suggests that interfragmentary compression actually does occur. We hypothesized that the use of a fully threaded screw does not produce any interfragmentary compression and that there is no difference in insertional torque between partially threaded and fully threaded screws. To test this hypothesis, fully and partially threaded 7.0 millimeter (mm) cannulated screws were placed across two synthetic bone blocks fabricated to simulate normal and osteoporotic bone. We compared two groups of normal and osteoporotic blocks for compression achieved and maximal insertional torque generated with fully threaded and partially threaded screw insertion. A micro computed tomography (CT) scan of the composite blocks was obtained to investigate for structural changes created during screw insertion. For both groups, compression was achieved with fully threaded screws and the maximal insertional torque was higher using fully threaded screws. Micro CT analysis demonstrated local bone damage with structural disruption in the near segment of the fully threaded screw path in comparison to the partially threaded. Clinical significance: this study demonstrates that compression is generated using fully threaded screws without using a predrilled glide hole. The insertional torque required to generate compression with fully threaded screws is increased but is clinically applicable. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1099–1105, 2018. … (more)
- Is Part Of:
- Journal of orthopaedic research. Volume 36:Issue 4(2018)
- Journal:
- Journal of orthopaedic research
- Issue:
- Volume 36:Issue 4(2018)
- Issue Display:
- Volume 36, Issue 4 (2018)
- Year:
- 2018
- Volume:
- 36
- Issue:
- 4
- Issue Sort Value:
- 2018-0036-0004-0000
- Page Start:
- 1099
- Page End:
- 1105
- Publication Date:
- 2017-10-04
- Subjects:
- fully threaded screws -- partially threaded screws -- sacral fracture -- interfragmentary compression
Orthopedics -- Periodicals
Musculoskeletal system -- Periodicals
616.7 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jor.23724 ↗
- Languages:
- English
- ISSNs:
- 0736-0266
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5027.665000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6410.xml