Development and validation of a stability‐indicating HPLC method for topiramate using a mixed‐mode column and charged aerosol detector. Issue 8 (20th February 2018)
- Record Type:
- Journal Article
- Title:
- Development and validation of a stability‐indicating HPLC method for topiramate using a mixed‐mode column and charged aerosol detector. Issue 8 (20th February 2018)
- Main Title:
- Development and validation of a stability‐indicating HPLC method for topiramate using a mixed‐mode column and charged aerosol detector
- Authors:
- Pinto, Eduardo Costa
Gonçalves, Mariana da Silva
Cabral, Lucio Mendes
Armstrong, Daniel W.
de Sousa, Valéria Pereira - Abstract:
- Abstract: The analysis of topiramate in the presence of its main degradation products is challenging due to the absence of chromophore moieties and their wide range of polarity. Mixed‐mode chromatography has been used in such cases because it combines two or more modes of separation. Charged aerosol detector is also an alternative since its detection is independent of optical properties and analyte ionization. This study is aimed to develop and validate two new stability‐indicating methods by high‐performance liquid chromatography for the main degradation products of topiramate using mixed‐mode chromatography and a charged aerosol detector. Method 1 employed an Acclaim Trinity P1® column (3.0 mm × 150 mm, 2.7 μm) with a mobile phase comprising of 80% ammonium acetate buffer (20 mM, pH 4.0) and 20% methanol at a flow rate of 0.5 mL/min at 35°C. Method 2 utilized a C18 Acclaim 120® column (4.6 mm × 250 mm; 5 μm) with ACN/water (50:50) at a flow rate of 0.6 mL/min at 50°C. Validation of the two methods demonstrated excellent performance with respect to linearity, precision, accuracy, and selectivity. The limits of detection for topiramate, fructose, sulfate, sulfamate, and compound A were 2.97, 12.08, 4.02, 13.91, and 3.94 μg/mL, respectively.
- Is Part Of:
- Journal of separation science. Volume 41:Issue 8(2018)
- Journal:
- Journal of separation science
- Issue:
- Volume 41:Issue 8(2018)
- Issue Display:
- Volume 41, Issue 8 (2018)
- Year:
- 2018
- Volume:
- 41
- Issue:
- 8
- Issue Sort Value:
- 2018-0041-0008-0000
- Page Start:
- 1716
- Page End:
- 1725
- Publication Date:
- 2018-02-20
- Subjects:
- charged aerosol detector -- degradation products -- impurities -- mixed‐mode chromatography -- topiramate
Separation (Technology) -- Periodicals
Chromatographic analysis -- Periodicals
543.089 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1615-9314 ↗
http://www.interscience.wiley.com/jpages/1615-9306 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jssc.201701340 ↗
- Languages:
- English
- ISSNs:
- 1615-9306
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5063.880000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: