Mechanical hemolysis in pediatric patients associated with rapid transfusion and one‐way valve. Issue 5 (1st March 2018)
- Record Type:
- Journal Article
- Title:
- Mechanical hemolysis in pediatric patients associated with rapid transfusion and one‐way valve. Issue 5 (1st March 2018)
- Main Title:
- Mechanical hemolysis in pediatric patients associated with rapid transfusion and one‐way valve
- Authors:
- Gniadek, Thomas J.
Richtsfeld, Martina
Pulkrabek, Shelley
Hansen, Kayla R.
Barnett, Susan L.
Joyner, Nitasha
Kinney, Stephanie
Zantek, Nicole D.
Azakie, Anthony
Cohn, Claudia S. - Abstract:
- Abstract : BACKGROUND: Four similar transfusion reactions involving infants were reported in less than 1 year. After transfusion of red blood cells (RBCs) via syringe in the operating room, each patient experienced discolored urine, laboratory evidence of hemolysis, and acute kidney injury. Clerical and serologic investigations were unremarkable. Mechanical hemolysis was considered. STUDY DESIGN AND METHODS: Simulated syringe transfusions were performed. Measurements included hematocrit (Hct), free hemoglobin, and visual hemolysis index. Washed and unwashed RBCs were tested with or without a recently introduced one‐way valve, using a 24‐ or 16‐gauge intravenous catheter. Constant manual pressure (1.43 ± 0.49 mL/sec) or syringe pump (2 mL/min) was used and a subset was timed. RESULTS: The valve increased hemolysis during manual transfusion using both catheters with washed and unwashed RBCs. With the 24‐gauge catheter, the change in Hct was –3.53 ± 0.69% with the valve and 0.22 ± 0.13% without (p < 0.00001). Comparing the individual valves tested, differences in hemolysis were observed (change in Hct, p < 0.0001). During manual transfusion with 24‐gauge catheter and unwashed RBCs, the degree of hemolysis was greater when it took longer to transfuse with a valve (change in Hct versus time, r = –0.75, p < 0.0001) compared to a slight increase in hemolysis for samples that took less time to transfuse without a valve (change in Hct versus time, r = 0.58, p = 0.23). CONCLUSIONS:Abstract : BACKGROUND: Four similar transfusion reactions involving infants were reported in less than 1 year. After transfusion of red blood cells (RBCs) via syringe in the operating room, each patient experienced discolored urine, laboratory evidence of hemolysis, and acute kidney injury. Clerical and serologic investigations were unremarkable. Mechanical hemolysis was considered. STUDY DESIGN AND METHODS: Simulated syringe transfusions were performed. Measurements included hematocrit (Hct), free hemoglobin, and visual hemolysis index. Washed and unwashed RBCs were tested with or without a recently introduced one‐way valve, using a 24‐ or 16‐gauge intravenous catheter. Constant manual pressure (1.43 ± 0.49 mL/sec) or syringe pump (2 mL/min) was used and a subset was timed. RESULTS: The valve increased hemolysis during manual transfusion using both catheters with washed and unwashed RBCs. With the 24‐gauge catheter, the change in Hct was –3.53 ± 0.69% with the valve and 0.22 ± 0.13% without (p < 0.00001). Comparing the individual valves tested, differences in hemolysis were observed (change in Hct, p < 0.0001). During manual transfusion with 24‐gauge catheter and unwashed RBCs, the degree of hemolysis was greater when it took longer to transfuse with a valve (change in Hct versus time, r = –0.75, p < 0.0001) compared to a slight increase in hemolysis for samples that took less time to transfuse without a valve (change in Hct versus time, r = 0.58, p = 0.23). CONCLUSIONS: Mechanical hemolysis should be considered when investigating possible hemolytic transfusion reactions, especially with high rates of transfusion and use of a valve. During rapid manual transfusion with the valve, greater resistance was associated with increased hemolysis. … (more)
- Is Part Of:
- Transfusion. Volume 58:Issue 5(2018)
- Journal:
- Transfusion
- Issue:
- Volume 58:Issue 5(2018)
- Issue Display:
- Volume 58, Issue 5 (2018)
- Year:
- 2018
- Volume:
- 58
- Issue:
- 5
- Issue Sort Value:
- 2018-0058-0005-0000
- Page Start:
- 1228
- Page End:
- 1233
- Publication Date:
- 2018-03-01
- Subjects:
- Hematology -- Periodicals
Blood -- Transfusion -- Periodicals
Blood Group Antigens -- Periodicals
Blood Preservation -- Periodicals
Blood Transfusion -- Periodicals
615 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1537-2995 ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=trf ↗
http://www.transfusion.org ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/trf.14554 ↗
- Languages:
- English
- ISSNs:
- 0041-1132
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9020.704000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 6403.xml