Feasibility of a streamlined imaging protocol in technetium-99m-Tektrotyd somatostatin receptor SPECT/CT. Issue 6 (June 2018)
- Record Type:
- Journal Article
- Title:
- Feasibility of a streamlined imaging protocol in technetium-99m-Tektrotyd somatostatin receptor SPECT/CT. Issue 6 (June 2018)
- Main Title:
- Feasibility of a streamlined imaging protocol in technetium-99m-Tektrotyd somatostatin receptor SPECT/CT
- Authors:
- Al-Chalabi, H.
Cook, A.
Ellis, C.
Patel, C.N.
Scarsbrook, A.F. - Abstract:
- Abstract : Aim: To assess the feasibility and efficacy of a streamlined single time-point 99m Tc-HYNIC-Tyr3-octreotide (Tektrotyd) somatostatin receptor scintigraphy (SRS) protocol to differentiate pathological uptake by neuroendocrine tumours (NETs) from physiological activity. Methods and materials: Tektrotyd imaging in 50 consecutive patients with NETs was reviewed retrospectively. Imaging was independently assessed by two experienced reporters with dual-certification in radiology and nuclear medicine and agreed in consensus. The presence of physiological bowel activity and/or further sites of equivocal uptake on 4-hour planar imaging and whether combined single-photon-emission computed tomography (SPECT)/computed tomography (CT) assessment allowed accurate diagnosis was tabulated. A judgement was also made in each case on whether 2-hour planar imaging was necessary for accurate diagnostic interpretation. Results: Thirty-six patients (72%) had positive findings on Tektrotyd SPECT/CT. Eight patients (16%) had bowel activity on 4-hour planar imaging, which could be considered to have hampered interpretation without access to SPECT/CT. Eleven studies in 10 patients (20%) demonstrated areas of indeterminate uptake on planar imaging; five in the uncinate process of the pancreas, three in the nasal cavity or paranasal sinuses, one in the adrenal glands, one in a focus of inflammation on the posterior abdominal wall, and one at the tip of a central venous line. In all cases,Abstract : Aim: To assess the feasibility and efficacy of a streamlined single time-point 99m Tc-HYNIC-Tyr3-octreotide (Tektrotyd) somatostatin receptor scintigraphy (SRS) protocol to differentiate pathological uptake by neuroendocrine tumours (NETs) from physiological activity. Methods and materials: Tektrotyd imaging in 50 consecutive patients with NETs was reviewed retrospectively. Imaging was independently assessed by two experienced reporters with dual-certification in radiology and nuclear medicine and agreed in consensus. The presence of physiological bowel activity and/or further sites of equivocal uptake on 4-hour planar imaging and whether combined single-photon-emission computed tomography (SPECT)/computed tomography (CT) assessment allowed accurate diagnosis was tabulated. A judgement was also made in each case on whether 2-hour planar imaging was necessary for accurate diagnostic interpretation. Results: Thirty-six patients (72%) had positive findings on Tektrotyd SPECT/CT. Eight patients (16%) had bowel activity on 4-hour planar imaging, which could be considered to have hampered interpretation without access to SPECT/CT. Eleven studies in 10 patients (20%) demonstrated areas of indeterminate uptake on planar imaging; five in the uncinate process of the pancreas, three in the nasal cavity or paranasal sinuses, one in the adrenal glands, one in a focus of inflammation on the posterior abdominal wall, and one at the tip of a central venous line. In all cases, accurate interpretation of findings was possible with SPECT/CT, without the 2-hour planar image. Conclusion: Two-hour planar imaging could be safely omitted from Tektrotyd SRS incorporating SPECT/CT imaging without reducing the accuracy of diagnostic interpretation. Streamlined imaging has the potential to reduce patient inconvenience and improve scanner and staff efficiency. Highlights: SPECT/CT improves accuracy of somatostatin receptor scintigraphy (SRS). A single time-point Tektrotyd SRS protocol has the potential to improve efficiency. 2-hour planar imaging could be safely omitted from Tektrotyd SRS including SPECT/CT. … (more)
- Is Part Of:
- Clinical radiology. Volume 73:Issue 6(2018)
- Journal:
- Clinical radiology
- Issue:
- Volume 73:Issue 6(2018)
- Issue Display:
- Volume 73, Issue 6 (2018)
- Year:
- 2018
- Volume:
- 73
- Issue:
- 6
- Issue Sort Value:
- 2018-0073-0006-0000
- Page Start:
- 527
- Page End:
- 534
- Publication Date:
- 2018-06
- Subjects:
- Medical radiology -- Periodicals
Radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiology -- Periodicals
Societies, Medical -- Periodicals
Medical radiology
Radiotherapy
Electronic journals
Periodicals
616.0757 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00099260 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.crad.2017.12.019 ↗
- Languages:
- English
- ISSNs:
- 0009-9260
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.350000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 6404.xml